Installation Instructions

Page!1!((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((Model:!BPT14-24AL-DSBN110/BPT14-24AL-DSORB110,!Menards!SKU:!611-3053/611-3054! !!!!!!!!
For!Customer!Support!please!email!:BXXI8MY:M83M7RDE87M3DG:IGBMDI4:WEIN,!or!ca ll !@ZZ Z H[> 2.Z?/Z.!Please!provide!th e!b a th !fan !m o d el!n umber!found!
on!the!front!of!this!manual!when!contacting!Customer!Support.!
!
(
GENERAL&SAFETY&INFORMATION&AND&WARNINGS
!
PI8(\IB8(:3V7M\(345(MI(74:B87(X8IX78(X78VI8N34E7(IV(MC7(B4DM](DM(D:(^78\(DNXI8M34M(MI(8735(
MC7:7(D4:M8BEMDI4:(E387V BGG\(A7 VI8 7(D4: M3GG3MDI4W(P 3DGB87 (MI(EI N X G\(Q DMC(MC7 (D4:M8 BEMDI4 :(
EI4M3D475(C787D4(EIBG5(87:BGM(D4(X78:I43G(D4_B8\(I8(X8IX78M\(53N3R7W(`7(87EINN745(MC3M(
\IB(F77X(MCD:(AIIFG7M(VI8(VBMB87(87V7874E7W(0GG(B4DM:(:CIBG5(A7(D4:M3GG75(A\(3(GDE74:75(
7G7EM8DED34W(
1. Electrical!service!supply!must!be!120V!60Hz.!
2. Wires!from!the!house!power!supply!to!the!unit!should!not!be!smaller!than!size!14!AWG.!
3. Follow!all!local!safety!and!electrical!codes,!as!well!as!requirements!for!NEC!(National!Electrical!Code)!and!
OSHA!(Occupational!Safety!and!Health!Act).!
4. This!unit!must!be!properly!grounded.!
5. This!unit!is!equipped!with!a!built-in!thermal!cut-off!for!safety!and!to!prolong!the!life!of!the!motor.!
6. Always!disconnect!the!power!supply!prior!to!servicing!the!fan,!motor!or!junction!box.!
7. Do!not!bend!or!kink!the!power!wires.!
8. Do!not!install!where!the!air!temperature!will!exceed!40
◦
!C!(104
◦
!F).!
9. This!ventilating!fan!is!approved!for!use!over!a!bathtub!or!shower!when!installed!in!a!GFCI-protected!
circuit.!
10. Do!not!use!to!exhaust!hazardous!or!explosive!vapors.!
11. Do!not!install!in!a!cooking!area.!
12. Use!this!unit!in!the!manner!intended!by!the!manufacturer.!If!you!have!any!questions,!please!call!Custo mer!
Support!at!(888)!930-8528.!
13. Installation!work!must!be!carried!out!by!qualified!person(s)!in!accordance!with!al l!l ocal !and !safety!codes,!
including!the!rules!for!fire-rated!construction.!
14. Exercise!care!not!to!damage!existing!wiring!when!cutting!or!drilling!into!walls!or!ceilings.!
15. Fans!should!always!be!vented!to!the!exterior/outside!of!the!home.!
16. Do!not!use!this!fan!with!any!solid-state!control!device.!
17. Prior!to!servicing!or!cleaning!this!unit,!shut!off!power!supply!at!the!panel!and!l ock!to!prevent!the!power!
from!being!turned!on.!If!the!panel!cannot!be!locked,!clearly!mark!the!panel!with!a!warning!tag!not!to!turn!
on!the!power.!
18. Ductwork!should!be!installed!in!as!straight!a!line!as!possib le,!with!min imu m!bends.!
19. Ductwork!size!must!be!a!minimum!of!the!discharge!and!should!not!be!reduced.!
20. The!fan!is!intended!to!be!mounted!at!least!7!feet!(2.1m)!above!the!floor.!
! !