Installation Instructions

Page%3%% Model:%BPT18-44A-CSBG150/200,%Menards%SKU:%611-3055%
For%Customer%Support%please%email%support@strategicretailsolutions.com,%or%c a ll%(8 88 )9 30 -8528.%Please%provide%the %ba th %fa n%model%numb er%fo u n d%
on%the%front%of%this%manual%when%contacting%Customer%Support.%
%
PLANNING&INSTALLATION&
When%installing%the%ventilation%fan%in%a%new%construction%site,%install%the%main%body%of%the%fan%and%ductwork%
during%the%rough-in%construction%of%the%building.%The%grille%should%be%installed%after%the%finished%ceiling%is%in%
place.%Use%the%dimensions%provided%in%this%manual%to%determine%the%required%hole%size%for%the%ceiling.%
The%ducting%from%this%fan%to%the%outside%of%the%building%has%a%strong%effect%on%the%airflow,%noise%and%energy-
use%of%the%fan.%Use%the%shortest,%straightest%duct%routing%possible%for%best%performance%and%avoid%installing%the%
fan%with%smaller%ducts%than%specified%in%this%manual.%Insulation%around%the%ducts%can%reduce%energy%loss%and%
inhibit%mold%growth.%Fans%installed%with%existing%ducts%may%not%achieve%their%rated%airflow.%Do%not%install%the%
ventilation%fan%in%areas%where%the%ductwork%will%require%configurations%as%shown%in%Fig.%1%below.%
%
%
%
Recommended%installation%includes%insulating%around%ductwork%and%the%fan%housing%to%minimize%heat%loss%(see%
Fig.%2%above).%Seal%all%gaps%around%the%housing%with%caulk%or%other%similar%material%to%inhibit%air%leakage%to%the%
exterior%of%the%thermal%envelope%of%the%building.%Rigid%sheet%metal%duct%and%the%shortest%path%to%the%outside%
will%minimize%static%pressure%losses%and%promote%adequate%air%flow.%
% %