Item Brochure

Tuttnauer manual autoclaves will
compliment any healthcare facility and
satisfy all of your sterilization needs.
The bright, new, easy to use panel was
designed with the operator in mind.
Time tested reliability and durability are
built into every Tuttnauer product.
Model 2540MK requires a voltage between 220V and 235V for proper
operation. When applicable a buck/boost transformer (0.5KVA) may be
required.
4
FEATURES:
Automatic shut off at the end of both the sterilization and dry cycles.
A long life electro polished chamber and door.
Double safety locking device prevents door from opening while chamber
is pr
essurized.
Drain valve is located on the front, allowing for quick and easy draining
of w
ater reservoir.
Dual safety thermostat to protect against overheating.
International certifications.
1 year parts and labor warranty.
The Tuttnauer M Series is also available in a quick cycle model, the
Kwiklave (MK). This sterilizer offers all the proven, dependable
features of our manual autoclave, with the added benefit of reducing
the total heat up time. This autoclave is the perfect choice for quick
instrument turnaround or a high volume office. Speed and reliability
are accomplished without sacrificing load size. 1 year parts and labor
warranty.
Large Capacity Manual Autoclave
Manual Kwiklave
TM
MK Series
Our largest manual tabletop autoclave. Perfect for multi-doctor
practices, clinics or surgery centers. 15" x 30" chamber accommodates
longer instruments or a large number of small instruments. Capacity
for 15 full size IMS cassettes. 1 year parts and labor warranty.
M Series
Item
No.
2340M
2540M
Chamber
Dimensions
Ø x L in(mm)
9" x 18"
(230 x 470)
10" x 19"
(254 x 475)
Overall
Dimensions
DxWxH in(mm)
21.5"x20"x14.4"
(545x510x365)
21.5"x20"x14.4"
(545x510x365)
Tray
Dimensions
DxWxH in(mm)
16.3"x6.7"x0.8"
(415x170x20)
16.3"x6.7"x0.8"
(415x170x20)
Volume
5gal/19L
6gal/23L
Standard
Cassette
Capacity
2 full and 2 half
3 full and 3 half
No. of
Trays
3
4
Standard
Unwrapped
Cycle Time
Cold: 27 mins
Hot: 13 mins
Cold: 30 mins
Hot: 14 mins
Voltage(V)
Freq.(Hz)
120V
50/60
120V
50/60
Power(W)
Current(A)
1400W
12A
1400W
12A
Shipping
Weight
lbs(kg)
85
(39)
85
(39)
Item
No.
3870M
Chamber
Dimensions
Ø x L in(mm)
15" x 30"
(384 x 760)
Overall
Dimensions
DxWxH in(mm)
34.5"x26"x20.6"
(875x665x525)
Tray
Dimensions
DxWxH in(mm)
26.6"x11.3"x1"
(675x286x25)
26.6"x13.8"x1"
(675x350x25)
Volume
22gal/85L
Standard
Cassette
Capacity
15 full
No. of
Trays
2
Standard
Unwrapped
Cycle Time
Cold: 32 mins
Hot: 23 mins
Voltage(V)
Freq.(Hz)
230V
50/60
Power(W)
Current(A)
3000W
13.6A
Shipping
Weight
lbs(kg)
209
(95)
2540MK
10" x 19"
(254 x 475)
21.5"x20"x14.4"
(545x510x365)
16.3"x6.7"x0.8"
(415x170x20)
6gal/23L 3 full and 3 half
4
Cold: 21 mins
Hot: 11 mins
230V
50/60
2200W
10A
85
(39)
1 Pressure Gauge
2 Timer
3 Thermostat
4 Function Selector
1
2
3
4
All published cycle times are estimated. Actual times may vary depending on load size and voltage.
Manual Autoclaves M/MK