Full Product Manual

18
FP14KC-X
JAN 2023
CAUTION! Locking Latches require compressed air pressure of 90 PSI Min to 115 PSI Max for
proper latch operation.
NOTE: To assemble airline tubing into push ttings, use rm pressure to push tubing into
tting until it bottoms out. Ensure tubing is cut square with no burrs, Fig 28.
7) Route and connect D6 Airlines to Lift for Latch operation, Fig. 27. Cut D6 airline to connect Air Fitting
to Air Valve. Connect airline from Air Fitting to Air Valve using Inlet Valve Port A, Figs. 27 A & B.
Fig. 27
8) Connect D6 Airline to the Outlet Valve Port P and route through Flex Tubing to connect to T Fitting.
Connect airlines to each end of T-Fitting, then connect to Y Fittings in Crossbeams, Figs. 27, 27-A &-B.
Fig. 27-A Fig. 27-B Fig. 28
Runway
Airline (D6)
Runway Airline (D6)
(Route thru Metal Rings)
LH Power Side Runway
Y Fitting
(Route Airline thru
Hole in
Crossbeam to Y Fitting)
T Fitting
Y Fitting
Air Cylinder
Air Cylinder
Air Valve
Airline (D6)
(See Details) Figs. 27 A & B
Inlet
D6 Airline to
Air Valve
Outlet
D6
Airline to
T Fitting
Quick
Disconnect
Air Fitting
Air Valve
(Push Button)
D6
Airline
Push
Sleeve
Airline
Push
Fitting
Air Valve
Crossbeam
Inlet
Port
Outlet
Port