Installation Guide

8
MR6K-48X
Dec 2017-A
STEP 2: Mounting Power Unit to Dolly
A. Remove power unit from the carton.
B. Use provided nuts & bolts to attach power unit to dollys mount plate (Fig. 3).
Fig. 3 Fig. 4
STEP 3: Hydraulic Hose Connection & Filling Reservoir Tank
A. Connect hydraulic hose to the pumps output port (Fig. 4).
B. Remove the black fill cap on reservoir tank and fill with 6 quarts of Non-Detergent / Non-
Foaming Hydraulic Oil - SAE-10, AW 32 or equivalent. Ensure not to fill past the MAX Fill
Line on the reservoir tank.
STEP 4: AC Power Supply Connection
A. Connect the 115VAC electrical power to the Power Units three prong electrical plug. Ensure to
use proper size extension cord and plug type for 20 Amps (Fig 5.)
B. Ensure power supply incorporates 20 Amp breaker service for safety.
Fig. 5
Power Unit
Electrical Cord