FOUNDATION and ANCHORING REQUIREMENTS, Fig 3
Drill holes using 3/4” Clean hole. Run nut down just Tighten nut with
carbide tipped
below impact section Torque wrench to
masonry drill bit per
of bolt. Drive anchor 130 ft.-lbs.
ANSI standard
into hole until nut and
B94.12.1977
washer contact base.
3.3 Tools & Equipment Required
• 12 quarts of Non-Detergent / Non-Foaming Hydraulic Oil - SAE-10, AW 32 or equivalent
• Chalk line and 12’ Tape Measure
• Concrete hammer drill with 3/4” bit
• 11/16” open end wrench
• 3/4” open end wrench
• Torque wrench
• 15/16” deep socket or wrench
• 1-1/8” socket
• 13/16” open end wrench
• Level (18” minimum length)
• Vise grips
• Tape measure
• Funnel
• Hoist or Forklift (optional)
• Two 12’ step ladders
• 1/4” drive ratchet with 5/16” socket