Installation Guide

20
TP11KC-DX
Jun 2017
Fig. 14b - Rear Arm
15. Fill the Tank
.
Remove the vent plug from the power unit and fill the reservoir with hydraulic oil. Make sure the funnel used to fill
the power unit is clean. Fill with Non-Detergent / Non-Foaming Hydraulic Oil - SAE-10, AW 32 or equivalent.
Replace the vent plug. The unit holds approximately ten quarts of fluid.
16. Lubricate the four inside corners of both columns with heavy duty grease.
17. Electrical Connection to POWER UNIT & OVERHEAD LIMIT SWITCH
A. Have a certified electrician make the electrical connection to the power unit. Use separate circuit for each
power unit, as shown below in the Wiring Diagram.
IMPORTANT! The wiring must comply with local code. Protect each circuit with time delay fuse or circuit breaker.
For 208V-230V single phase, use 20 amp fuse.
WARNING!! Never operate the motor in line voltage less than 208VAC as motor damage may occur.
B. Have a certified electrician make the electrical connection for the K2 overhead limit switch to power unit’s
switch box, as shown below.