4.2 Maintenance Instructions
Contact your service provider for instruction before starting up if you are not completely familiar with
automotive lift maintenance procedures. Only qualified personnel can perform maintenance on this
equipment. Any failure in operation may cause personal injury or death.
Daily
Always keep bolts tight. Check periodically.
Always keep lift components clean.
Always if oil leakage is observed, contact your service provider.
Check cables and sheaves for wear every day. Replace worn or broken parts with lift manufacturer’s
parts, or their equivalent.
Monthly
Check equalizer cable tension.
Lubricate locking latch shafts. Push latch handle several times for oil to penetrate joints.
Lubricate the four inside corners of the columns with heavy duty bearing grease.
With lift lowered, check the hydraulic fluid level. If necessary add oil as described in the Installation
Instruction section of this manual
Check carriage latch synching: Latches should click at the same time. If necessary adjust equalization
cables.
Check tightness of all bolts.
Check the nuts for tightness every week for the first month, and every month afterwards.
Every 3 Months
Check anchor bolts for tightness. Anchors should be torqued to 130 ft.-lbs.
Check and clean the oil filter
Every 6 Months
Check fluid level of lift power unit and refill if required.
If Lift stops short of full rise or chatters, contact your service provider.
Replace all caution, warning or safety related decals on the lift if unable to read or missing. Reorder