InstallationInstructions
IndependentCombustibleGas
DetectorUserManual
(MeasurementRange:0%to100%LEL)
ProductDescription
Pressandholdthe
buttonfor5s.
EnteringtheNetworkConfigurationMode
1.Powerontheproduct.
Airintakevent
Statusindicator
Pressthebuttonto
startasimulationtest.
Pressandholdthebutton
toresettheproduct.
Powerport
Buzzer
Airexchangewindow
Mounting
base
2.Pressandholdthebuttonfor5storestoretheproducttofactory
settings.
Thestatusindicatorwillrapidlyblinkgreenandtheproductwillenter
thenetworkconfigurationmodeautomaticallyoncethefactorysettings
havebeenrestored.
Connecttheproducttothepowersupply.
Pressandholdthebuttonforover5stomaketheproductenterthenetwork
configurationmodeandstartdetection.Thestatusindicatorwillrapidly
blinkgreen.Iftheproducthasenteredthenetworkconfigurationmode,the
statusindicatorwillbesteadygreenfor5sandthenoff.
Iftheproductfailstoenterthenetworkconfigurationmodewithin60s,the
statusindicatorwillbesteadyyellowfor5sandthenoff.
IndicatorandBuzzerStates
Theindicatorblinksred.
Thebuzzerbeeps.
PackingList
Onepoweradapter
Oneusermanual Twoexpansiontubesandtwoscrews
Oneproductqualificationcertificate
Onecombustiblegasdetector
One3Msticker
Indepen dentComb usti ble
GasD etect orUserMan ual
(Mea suremen tRang e:
0%to10 0%LE L)
2.Installationpositions
Grayarea:
optimalceiling-mounting
area
Ceiling
Gasstove
Gasdetector
About0.2m
to0
.6m
Gasdetector
Ground
Optimalwall-mounted
installationposition
Ceilingmount:Installtheproductintheannularzoneabout1.5mto
3mabovethegassource.
Wallmount:Installtheproductonawall,about0.2mto0.6mbelow
theceilingand1.5mawayfromthegassource.
90°
3.Installationmethods
Affixthe3Mstickertotherear
ofthemountingbase.
3
M
3M
Rotatetheproductclockwise
intothemountingbase.
(1)Usingscrews
(2)Usinga3Msticker
Affixtheproducttothe
targetposition.
Usescrewstofixthemounting
basetotheceilingorwall.
1.Precautions
(1)Installtheproductindoorswheredevicesusecombustible
gas(methane).
(2)Donotinstalltheproductoutdoors.
(3)Ensurethatthetemperatureoftheinstallationenvironment
iswithintherangeof‒1Cto+55°C.
(4)Donotinstalltheproductinplaceswheretheproductwillbe
affectedbyheat,steam,orsmokeresidualgeneratedbygas
appliances(forexample,aboveagasstove).
(5)Ensurethattherearenoobstaclesbetweentheproductand
gasdevices,ortheproductmayfailtodetectgasleakage.
(6)Donotinstalltheproductinplaceswithalargeairflow,suchas
airintakevents,ventilators,windows,anddoors,ortheproduct
mayfailtodetectgasleakage.
(7)Ensurethattheproductisproperlyconnectedtoapower
socketandthatthepowersockethaspower.
(8)Youareadvisedtousescrewstoinstalltheproduct.Ifyouuse
a3Mstickertoinstalltheproduct,anyproductdamageorsafety
accidentsincurredtherefromwillbeyourresponsibility.However,
ifyouchoosetousea3Msticker,affixtheproducttoasmooth,
even,dry,andcleansurface.
(9)Regularlycheckwhethertheproductisattachedtothesurface
securelytopreventitfromfallingdown.
UsingthisProduct
1.Preheatingstate
Theproductentersthepreheatingstateafterbeingpoweredon.
Duringthepreheatingperiod,thestatusindicatorisflashingyellow
lights.Afterpreheatingiscompleted(nomorethan3minutes),
thestatusindicatorwillbecomesteadygreen.
2.Workingstate
Whentheproductisworkingproperly,thestatusindicatorwillbe
steadygreenwithnoalarmsound.
3.Alarmstate
If the product is working properly and the gas concentration is
higher than the preset alarm threshold, the indicator will be steady
red and the buzzer will generate an audible alarm.
4.Faultystate
Iftheproductisfaulty,theindicatorwillbesteadyyellowandthe
buzzerwillgeneratealongblastofsound.
5.Simulationtest
Whentheproductisworking,pressthemute/self-diagnostic
buttontoenterthesimulationtestmode.Afterenteringthe
simulationtestmode,theproductwillsendawirelessalarmsignal.
Afterthetestiscompleted,theproductwillsendawirelessalarm
clearancesignal.
Afteryouunpacktheproductpackage,checkwhethertheproductisintactandthatall
accessoriesareincludedandcomplete.Thefollowingfiguresshowtheitemsthatshould
becontainedintheproductpackage.
Theindicatoralternates
greenandyellow.
Theindicatorissteadygreen.
Theindicatorissteadyyellow.
Theindicatorissteadyred.
Theindicatorrapidly
blinksgreen.
Thebuzzerdoesnot
makeasound.
Thebuzzerdoesnot
makeasound.
Thebuzzergenerates
alongblastofsound.
Thebuzzerbeeps.
Thebuzzerdoesnot
makeasound.
Theproductgenerates
agasleakagealarm.
Theproductisbeingpreheated.
Theproductisworkingproperly.
Theproducthasaninternalfault.
Theproductisin
self-diagnosticstate.
Theproductisinnetwork
configurationmode.
Qualification