Specifications

C2-1000 SERIES OPERATION MANUAL
66
Board temp. (deg.C) 0CD Read only
Air temp. (deg.C) 148 Read only
Regulators temp.(deg.C) 147 Read only
PLD temp. (deg.C) 111 Read only
Fan speed (rpm) 0CE Read only
Led brightness 12C 0..100
LCD backlight 200 0..1 = Off, On
Serial type
(See Specs to see if your
unit supports all options)
251 0 = RS-232
1 = RS-422
2 = RS-485
RS232 Baud rate 0AB 0..6 = 9600, 19200, 28800, 33600, 38400,
57600, 115200
TAC number 0 15D Read only
TAC number 1 15E Read only
TAC number 2 15F Read only
TAC number 3 160 Read only
TAC number 4 161 Read only
TAC number 5 162 Read only
MAC number (IP port) 208 Read only bytes reversed!
Not part of menu system
Front panel lock 0FC 0 = unlocked, 1 = locked
Emulate button press 24F See section below.
Options installed or
attached read only
264 24-bit number has a bit high to indicate that
a unit is attached, or an option installed:
Bit Unit Bit Unit
0 Audio switcher 12 S2-110CV
1 S2-106AD 13 S2-110YC
2 S2-105PC 14 S1-101AA
3 S2-105PCA 15 Ethernet
4 S2-109PC 16 Tally / UMD module
5 S2-105CV 17 -
6 S2-105CVA 18 -
7 S2-105YC 19 -
8 S2-105YCA 20 -
9 - 21 -
10 S2-108HD 22 -
11 S2-105DVIA 23 -
10.4 Examples
Each example shows the packet sent to the unit and its response. When a byte is
not required to be sent it is indicated by a ‘- ‘in the table below (since a Read is 6
bytes shorter than a Write). Each character shown below is sent as a ASCII
character so F0400 is sent as ‘F’ ‘0’ ‘4’ ‘0’ ‘0’.
Packet sent Packet returned
SOP CMD CHA WIN OUT FUN PAY CS EOP SOP CMD CHA WIN OUT FUN PAY CS EOP