Specifications

C2-1000 SERIES OPERATION MANUAL
69
F 04 02 42 00 F1 000001 3A CR F 44 02 42 00 F1 000001 7A CR
Write the function for first item in macro 3 = Zoom
F 04 02 42 00 F3 000086 C1 CR F 44 02 42 00 F3 000011 01 CR
Write data for the first item = 100
F 04 02 42 00 F2 000064 9E CR F 44 02 42 00 F2 000011 DE CR
Write the function for the second = shrink
F 04 02 42 00 F3 000087 C2 CR F 44 02 42 00 F2 000011 02 CR
Write the data for the second item = 100
F 04 02 42 00 F2 000064 9E CR F 44 02 42 00 F3 000011 DE CR
10.5.3 Run and Restore macros
Macros once programmed can be run by sending one of the following commands.
By running macro 5 the unit can be restored to its previously saved state, when used
in conjunction with the other macros this allows a default setup or baseline for the
unit to be created.
Packet sent Packet returned
SOP CMD CHA WIN OUT FUN PAY CS EOP SOP CMD CHA WIN OUT FUN PAY CS EOP
Restore
F 04 05 42 00 F1 000000 3C CR F 44 05 42 00 F1 000000 7C CR
Run macro 1
F 04 00 42 00 F1 000000 37 CR F 44 00 42 00 F1 000000 77 CR
Run macro 2
F 04 01 42 00 F1 000000 38 CR F 44 01 42 00 F1 000000 78 CR
Run macro 3
F 04 02 42 00 F1 000000 39 CR F 44 02 42 00 F1 000000 79 CR
Run macro 7
F 04 07 42 00 F1 000000 39 3E F 44 02 42 00 F1 000000 7E CR
10.5.4 Emulate a front panel button press
This is performed using function code 0x24F and the following payload codes
(requires firmware version 287 onwards). Note that not all button presses are
relevant to your unit.
Button press Payload
Power down 0400E1
Power back on – see Reset command. N/A
Reset menu settings to power-on values 0100E2
Reset menu settings to factory defaults 2300E2
Lock / unlock front panel buttons 0100E3
Set to NTSC output 0000E7
Set to PAL output 0000E8
Set to default output resolution for unit 0000E9
Set to 480p output 0000EA
Set to 720p 59.94Hz output 0000EB