User Manual

Manual 0-2529 3 - 9 OPERATION
Air secondary is normally used when operating with air
plasma and occasionally with nitrogen plasma.
Inexpensive - reduces operating costs.
Improves cut quality on some ferrous materials.
AIR SECONDARY
•CO2 secondary is used with nitrogen or Ar/H2 plasma.
Provides good cut quality on ferrous or non-ferrous
materials.
May reduce smoke when used with Ar/H
2 plasma.
CO
2 SECONDARY
Nitrogen secondary is used with Ar/H2 plasma.
Provides smooth finishes on non-ferrous materials.
May be used with nitrogen plasma in order to operate
from one compressed gas cylinder.
May reduce smoke when used with Ar/H
2 plasma.
NITROGEN
SECONDARY
Water secondary should be used only in mechanized
applications - never in hand cutting!
Normally used with nitrogen, Ar/H
2, or air plasma.
Provides very smooth cut surface.
Reduces smoke and heat input to the workpiece.
Effective up to 1 inch maximum material thickness.
Tap water provides low operating expense.
WATER SECONDARY
Table 3-B Secondary Selection for Plasma Cutting