OPERATION 3 - 14 Manual 0-2529
Four two-pole DIP switches located on the control logic PC
board control the auto-restart functions.
Auto-Restart
(continued)
Auto-Restart SW1-1 SW1-2
Mode Position Position
Normal 0 (Off) 0 (Off)
Disabled 0 (Off) 1 (On)
1 (On) 0 (Off)
1 (On) 1 (On)
On/Off (SW1)
Note: Either pole set to 1(on)
disables auto-restart function
Auto-Restart SW2-1 SW2-2
Mode Position Position
Normal 0 (Off) 0 (Off)
Delayed 0 (Off) 1 (On)
1 (On) 0 (Off)
1 (On) 1 (On)
Pre-Flow Time SW3-1 SW3-2
(Seconds) Position Position
2 0 (Off) 0 (Off)
4 0 (Off) 1 (On)
7 1 (On) 0 (Off)
10 1 (On) 1 (On)
Post-Flow Time SW4-1 SW4-2
(Seconds) Position Position
1.25 0 (Off) 1 (On)
2.5 0 (Off) 0 (Off)
5 1 (On) 0 (Off)
10 1 (On) 1 (On)
Post-Flow Time SW4-1 SW4-2
(Seconds) Position Position
5 0 (Off) 1 (On)
10 0 (Off) 0 (Off)
20 1 (On) 0 (Off)
40 1 (On) 1 (On)
Normal/Delayed (SW2)
Note: Either pole set to 1(on)
sets auto-restart function
Pre-Flow Delay (SW3)
Post-Flow Delay (SW4)
For Hand Cutting
Systems (A1845-01)
with 19x704 Logic PCB
Post-Flow Delay (SW4)
For Machine Cutting
Systems (A1845-15)
with 19x910 Logic PCB