qwt-120 wire cutting station English Français Español installation and Operation guide Version No: AA.
WE APPRECIATE YOUR BUSINESS! Congratulations on your new Tweco® Robotics product. We are proud to have you as our customer and will strive to provide you with the best service and reliability in the industry. This product is backed by our extensive warranty and world-wide service network. To locate your nearest distributor or service agency, please contact a representative at the address and phone number in your area listed on the inside back cover of this manual, or visit us on the web at www.tweco.com.
WARNING Read and understand this entire Manual and your employer’s safety practices before installing, operating, or servicing the equipment. While the information contained in this Manual represents the Manufacturer’s best judgment, the Manufacturer assumes no liability for its use. Wire Cutting Station Installation and Operation Guide Instruction Manual Number SM-QWT-120 Published by: Tweco® Products Inc. 2800 Airport Road Denton, TX 76208 (940) 566-2000 www.tweco.
wire cutting station Table of Contents SECTION 1: SAFETY INSTRUCTIONS AND WARNINGS........................................... 1-1 1.01 Welding Hazards........................................................................................1-1 1.02 Principal Safety Standards.........................................................................1-3 1.03 Safety and Health.......................................................................................1-3 SECTION 2: INTRODUCTION AND DESCRIPTION..........
wire cutting station SECTION 1: SAFETY INSTRUCTIONS AND WARNINGS WARNING SERIOUS INJURY OR DEATH may result if welding and cutting equipment is not properly installed, used and maintained. Misuse of this equipment and other unsafe practices can be hazardous. The operator, supervisor, and helper must read and understand the following safety warnings and instructions before installing or using any welding or cutting equipment.
wire cutting station 11. Keep smoke, fumes, and gases from the breathing area. 12. Fumes from the welding or cutting process are of various types and strengths, depending on the kind of base metal being worked on. To ensure your safety, do not breathe these fumes. 13. Ventilation must be adequate to remove smoke, fumes, and gases during the operation to protect operators and other personnel in the area. 14.
wire cutting station 1.02 Principal Safety Standards SAFETY AND OPERATING REFERENCES 1. Code of Federal Regulations. (OSHA) Section 29 Part 1910.95, 132, 133, 134, 139, 251, 252, 253, 254 and 1000. U.S. Government Printing Office, Washington, DC. 20402. 2. ANSl Z49.1 “Safety In Welding and Cutting”. 3. ANSI Z87.1 “Practice for Occupational and Educational Eye and Face Protection”. 4. ANSl Z88.2 “Standard Practice for Respiratory Protection”.
wire cutting station SECTION 2: INTRODUCTION AND DESCRIPTION 2.01 How to Use this Manual 2.04 Features To ensure safe operation, read the entire manual, including the chapters on safety instructions and warnings. Throughout this manual, the words WARNING, CAUTION, and NOTE may appear. Pay particular attention to the information provided under these headings. These special annotations are easily recognized as follows: • Machined discs from heat-treated tool steel for long life and economical performance.
wire cutting station Section 3: Installation and Operation 1. Remove the QWT-120 Wire Trimmer from the shipping carton. 2. Mount the QWT-120 unit onto a solid work table within the envelope of the robot. Note The cutting path should be within reach of the end of the welding wire, at the desired angle of cut. The unit may be mounted in a vertical upright position, or at an angle of up to 30°. The mounting plate has four .
wire cutting station SECTION 4: wiring diagram Wiring Diagram switch (momentary) test Off Auto signal 24v dc black red cap R1 control wire R2 blue 120 v AC wiring diagram power cord brown R3 8 3 1 motor R4 5 4 2 green 4-6 SM-QWT-120
wire cutting station SECTION 5: replacement parts Part No. QWT-120-20 (Stock No. 3500-1320) Part No. QWT-120-9 (Stock No. 3500-1309) Part No. QWT-120-4 (Stock No. 3500-1304) Part No. QWT-120-2 (Stock No. 3500-1302) Part No. QWT-120-6 (Stock No. 3500-1306) Part No. QWT-120-19 (Stock No.
wire cutting station SECTION 6: FACTORY REPAIR CENTER Tweco® Robotics Factory Repair Center (FRC) offers a repair service for our customers on the various cable assemblies and peripheral products. The majority of our consumers do not want to spend the time involved with repairs and generally do not have the necessary equipment and tools to perform repairs.
Statement of Warranty LIMITED WARRANTY: THERMADYNE® warrants that its products will be free of defects in workmanship or material.
Warranty SCHEDULE The warranty is effective below for the time stated in the Warranty Schedule beginning on the date that the authorized distributor delivers the products to the purchaser. THERMADYNE® reserves the right to request documented evidence of date of purchase. Engine Driven Welders Scout®, Raider®, Explorer™ Original Main Power Stators and Inductors Original Main Power Rectifiers, Control P.C.
GLOBAL CUSTOMER SERVICE CONTACT INFORMATION Thermadyne USA 2800 Airport Road Denton, TX 76207 USA Telephone: (1) 800-535-1888 Fax: (1) 800-535-0557 Thermadyne Asia Sdn Bhd Lot 151, Jalan Industri 3/5A Rawang Integrated Industrial Park - Jln Batu Arang 48000 Rawang Selangor Darul Ehsan West Malaysia Telephone: 603+ 6092 2988 Fax : 603+ 6092 1085 Thermadyne Canada 2070 Wyecroft Road Oakville, Ontario Canada, L6L5V6 Telephone: (1) 905-827-9777 Fax: (1) 905-827-9797 Cigweld Australia 71 Gower Street Preston,
World Headquarters Thermadyne Holdings Corporation Suite 300, 16052 Swingley Ridge Road St. Louis, MO 63017 Telephone: (636) 728-3000 Fascimile: (636) 728-3010 www.thermadyne.