Flow Rates
200A
N₂ (SLPM / SCFH) H₂O (GPH / LPH)
Preow
13 / 28 5 / 19
N₂ Plasma / H₂O Shield
Culow
28 / 59 5 / 19
Shield Retainer Shield Cap
Shield Gas
Distributor
Tip Plasma Gas Distributor Electrode Cartridge
21-1015 21-1049 21-1284 21-1067 21-1043 21-1089 21-1022
GCM-2010 SC-3000 Torch Height Control (THC) Basic THC CNC Control
Material
Thickness
Pre Flow
Pressure
(N₂)
Cut Flow Rates / Pressures
Arc
Voltage
Cut Height
THC
Pierce
Delay
Pierce
Ignion
Height
Elevaon
Height
Control
Delay
Pierce
Height
without
Elevaon
Travel
Speed
CNC
Moon
Delay
Max Kerf Width
@ Rec. Speed
Plasma (N₂) Shield (H₂O)
ga (in) inch (psi) Ball (psi) Ball (psi)* (Volts) (in) ±0.005 (sec) (in) (in) (sec) (in) (ipm) (sec) (in)
- 1/2 0.500 20 100 90 5 55 168 0.250 0.3 0.200 0.150 0.2 0.300 110 0.3 0.120
- 5/8 0.625 20 80 100 5 55 170 0.300 0.7 0.250 0.200 0.2 0.350 105 0.5 0.126
- 3/4 0.750 20 80 100 5 55 175 0.300 0.9 0.250 0.200 0.2 0.350 90 0.6 0.127
- 7/8 0.875 20 80 100 5 55 180 0.300 1.2 0.250 0.200 0.2 0.350 75 0.8 0.133
- 1 1.000 20 80 100 5 55 194 0.350 1.6 0.300 0.250 0.2 0.400 50 1.0 0.144
- 1 1/4 1.250 20 80 100 5 55 208 0.400 3.4 0.350 0.300 0.2 0.450 25 2.0 0.180
- 1 1/2 1.500 20 80 100 5 55 210 0.400 0.8 Edge Start 0.2 Edge 20 0.8 0.197
- 1 3/4 1.750 20 80 100 5 55 212 0.400 0.8 Edge Start 0.2 Edge 18 0.8 0.201
- 2 2.000 20 80 100 5 55 215 0.400 0.8 Edge Start 0.2 Edge 12 0.8 0.204
GCM-2010 SC-3000 Torch Height Control (THC) Basic THC CNC Control
Material
Thickness
Pre Flow
Pressure
(N₂)
Cut Flow Rates / Pressures
Arc
Voltage
Cut Height
THC
Pierce
Delay
Pierce
Ignion
Height
Elevaon
Height
Control
Delay
Pierce
Height
without
Elevaon
Travel
Speed
CNC
Moon
Delay
Max Kerf Width
@ Rec. Speed
Plasma (N₂) Shield (H₂O)
(mm) (Bar) Ball (Bar) Ball (Bar)* (Volts) (mm) ±0.1 (sec) (mm) (mm) (sec) (mm)
(mm/
min)
(sec) (mm)
12 1.4 100 6.1 5 3.8 168 6.1 0.2 4.8 3.5 0.2 7.3 2820 0.3 3.0
15 1.4 85 6.7 5 3.8 169 7.3 0.6 6.0 4.7 0.2 8.5 2700 0.4 3.2
20 1.4 80 6.9 5 3.8 176 7.6 1.0 6.4 5.1 0.2 8.9 2170 0.7 3.3
25 1.4 80 6.9 5 3.8 192 8.7 1.5 7.5 6.2 0.2 10.0 1350 1.0 3.6
30 1.4 80 6.9 5 3.8 204 9.8 2.9 8.5 7.3 0.2 11.1 810 1.7 4.3
35 1.4 80 6.9 5 3.8 209 10.2 0.8 Edge Start 0.2 Edge 530 0.8 5.0
40 1.4 80 6.9 5 3.8 211 10.2 0.8 Edge Start 0.2 Edge 490 0.8 5.0
50 1.4 80 6.9 5 3.8 215 10.2 0.8 Edge Start 0.2 Edge 320 0.8 5.2
Marking
Pre Flow
Pressure
(N₂)
Marking Flow Rates /
Pressures
Arc
Voltage
Marking
Height
Pierce Ignion Height
THC and CNC
Delay
Control
Delay
Travel
Speed
Marking quality
degrades as
thickness
decreases.
20A Arc Current
Plasma (N₂) Shield (N₂)
Burn-through may
happen for thicknesses
< 1/16” (0.063”) /
1.6 mm.
(psi) /
(Bar)
Ball
(psi) /
(Bar)
Ball
(psi) /
(Bar)
(Volts)
(in) ±0.005 /
(mm) ±0.1
(in) ±0.005 / (mm) ±0.1 (sec) (sec)
(ipm) /
(mm/ min)
15 / 1.0 80
60 /
4.1
NA
80 /
5.5
140 0.120 / 3.0 0.120 / 3.0 0 0.4
300 /
7620
BOLD TYPE indicates maximum piercing parameters. BOLD ITALIC indicates edge starts only.
* Pressure of the water supply line should be regulated by customer pressure regulator.
Note 1: Ohmic height sensing is not recommended with water shield. Water on the plate interferes electrically with the ohmic sensing circuit.
Note 2: Water source used for shield must be demineralized.
Cartridge
Electrode
Shield
Shield Gas
Distributor
Tip
Plasma Gas
Distributor
Shield Retainer
Art # A-07917_AC
This Art Is For Reference ONLY