Owner's manual
Manual 0-4828 Rev BA 8-45 TORCH DATA for Ultra-Cut
Stainless Steel
Flow Rates
200A Bevel Cut
N₂ (SLPM / SCFH) H₂O (GPH / LPH)
Preow
13 / 28 5 / 19
N₂ Plasma / H₂O Shield
Culow
25 / 53 5 / 19
Shield Retainer Shield Cap
Shield Gas
Distributor
Tip Plasma Gas Distributor Electrode Cartridge
21-1015 21-1049 21-1284 21-1067 21-1043 21-1089 21-1022
GCM-2010 SC-3000 Torch Height Control (THC) Basic THC CNC Control
Eecve
Material
Thickness
Min.
Clearance
Pre Flow
Pressure
(N₂)
Cut Flow Rates / Pressures
Eecve Cut
Height
THC
Pierce
Delay
Pierce
Ignion
Height
Elevaon
Height
Control
Delay
Pierce
Height
without
Elevaon
Travel
Speed
CNC
Moon
Delay
Max Kerf Width
@ Rec. Speed
Plasma (N₂) Shield (H₂O)
inch (in) (psi) Ball (psi) Ball (psi)* (in) (sec) (in) (in) (sec) (in) (ipm) (sec) (in)
0.375 0.080 20 80 90 5 55 0.160 - 0.550 0.1 0.200 0.150 0.4 0.300 95 0.1 0.110
0.500 0.080 20 80 90 5 55 0.160 - 0.550 0.4 0.200 0.150 0.2 0.300 85 0.4 0.115
0.625 0.080 20 80 90 5 55 0.180 - 0.550 0.8 0.200 0.150 0.2 0.300 65 0.5 0.122
0.750 0.080 20 80 90 5 55 0.200 - 0.550 1.2 0.200 0.150 0.2 0.300 50 0.7 0.133
0.875 0.080 20 80 90 5 55 0.250 - 0.550 1.7 0.300 0.250 0.2 0.400 40 0.9 0.149
1.000 0.080 20 80 90 5 55 0.300 - 0.550 1.9 0.350 0.300 0.2 0.450 35 1.0 0.148
1.250 0.080 20 80 90 5 55 0.300 - 0.550 0.4 Edge Start 0.2 Edge 20 0.4 0.176
1.500 0.080 20 80 90 5 55 0.350 - 0.450 0.4 Edge Start 0.2 Edge 10 0.4 0.211
1.750 0.080 20 80 90 5 55 0.350 - 0.450 0.4 Edge Start 0.2 Edge 8 0.4 0.216
GCM-2010 SC-3000 Torch Height Control (THC) Basic THC CNC Control
Eecve
Material
Thickness
Min.
Clearance
Pre Flow
Pressure
(N₂)
Cut Flow Rates / Pressures
Eecve Cut
Height
THC
Pierce
Delay
Pierce
Ignion
Height
Elevaon
Height
Control
Delay
Pierce
Height
without
Elevaon
Travel
Speed
CNC
Moon
Delay
Max Kerf Width
@ Rec. Speed
Plasma (N₂) Shield (H₂O)
(mm) (mm) (Bar) Ball (Bar) Ball (Bar)* (mm) (sec) (mm) (mm) (sec) (mm)
(mm/
min)
(sec) (mm)
10 2.0 1.4 80 6.2 5 3.8 4.1 - 14.0 0.1 5.1 3.8 0.4 7.6 2380 0.1 2.8
15 2.0 1.4 80 6.2 5 3.8 4.4 - 14.0 0.7 5.1 3.8 0.2 7.6 1790 0.5 3.0
20 2.0 1.4 80 6.2 5 3.8 5.5 - 14.0 1.3 5.8 4.6 0.2 8.4 1190 0.8 3.5
25 2.0 1.4 80 6.2 5 3.8 7.5 - 14.0 1.9 8.7 7.5 0.2 11.3 910 1.0 3.8
30 2.0 1.4 80 6.2 5 3.8 7.3 - 14.0 0.4 Edge Start 0.2 Edge 580 0.4 4.2
35 2.0 1.4 80 6.2 5 3.8 8.3 - 11.4 0.4 Edge Start 0.2 Edge 380 0.4 4.9
40 2.0 1.4 80 6.2 5 3.8 8.9 - 11.4 0.4 Edge Start 0.2 Edge 240 0.4 5.4
BOLD TYPE indicates maximum piercing parameters. BOLD ITALIC indicates edge starts only.
* Pressure of the water supply line should be regulated by customer pressure regulator.
Note 1: Ohmic height sensing is not recommended with water shield. Water on the plate interferes electrically with the ohmic sensing circuit.
Note 2: Water source used for shield must be demineralized.
Cartridge
Electrode
Shield
Shield Gas
Distributor
Tip
Plasma Gas
Distributor
Shield Retainer
Art # A-08552
This Art Is For Reference ONLY