Manual
Manual 0-4802 Rev. AJ 8-31 TORCH DATA
Aluminum
150A
N
2
Plasma / H
2
0 Shield
Cartridge
22-1020
Electrode
22-1081
Plasma
Gas Distributor
22-1041
Tip
22-1092
Shield Cup
22-1016
Art # A-06811
Shield
Gas Distributor
22-1278
Shield Cap
22-1048
(in) inch (PSI) Ball (PSI) Ball (PSI) * Volts
(in)
±0.005
(ipm) (in) (sec) (in)
3/16 0.188 70 60 90 8 55 130 0.100 150 0.350 0.2 0.107
1/4 0.250 70 60 90 8 55 133 0.120 120 0.350 0.2 0.108
3/8 0.375 70 60 90 8 55 140 0.120 100 0.350 0.2 0.116
1/2 0.500 70 60 90 8 55 152 0.200 75 0.350 0.3 0.126
5/8 0.625 70 60 90 8 55 155 0.200 50 0.350 0.4 0.142
3/4 0.750 70 60 90 8 55 165 0.250 35 0.350 0.5 0.141
1 1.000 70 60 90 8 55 178 0.300 20 0.350 1.0 0.155
(Bar) Ball (Bar) Ball (Bar) * Volts
(mm)
±0.1
(mm/mi
n)
(mm) (sec) (mm)
4.8 60 6.2 8 3.8 130 2.5 3700 8.9 0.2 2.7
4.8 60 6.2 8 3.8 132 3.0 3220 8.9 0.2 2.7
4.8 60 6.2 8 3.8 137 3.0 2785 8.9 0.2 2.8
4.8 60 6.2 8 3.8 142 3.0 2445 8.9 0.2 2.9
4.8 60 6.2 8 3.8 149 5.1 2050 8.9 0.3 3.2
4.8 60 6.2 8 3.8 154 5.1 1445 8.9 0.4 3.4
4.8 60 6.2 8 3.8 167 6.4 830 8.9 0.5 3.7
4.8 60 6.2 8 3.8 177 7.6 535 8.9 1.0 3.9
NOTE 1
: Ohmic height sensing is not recommended with water shield.
Water on the plate interferes electrically with the ohmic sensing circuit.
* Pressure of the water supply line should be regulated by customer supplied pressure regulator
12
15
20
25
5
6
8
10
Travel
Speed
Initial
Piercing
Height
Pierce
Delay
Material
Thickness
Pre Flow
Pressure
(N
2
) Plasma (N
2
) Shield (H
2
O)
Torch
Working
Height
Cut Flow Rates / Pressures
Arc
Voltage
Torch
Working
Height
Travel
Speed
Initial
Piercing
Height
Pierce
Delay
NOTE 2
: Water source used for H
2
O Water Shield must be demineralized.
Kerf
Width
@ Rec.
Speed
150A Aluminum (N
2
/H
2
O)
Material
Thickness
Pre Flow
Pressure
(N
2
)
Cut Flow Rates / Pressures
Arc
Voltage
Kerf
Width
@ Rec.
Speed
Plasma (N
2
) Shield (H
2