Owner's manual
TORCH DATA for Ultra-Cut 8-48 Manual 0-4829 Rev AN
(ga) (in) inch (PSI) (Ball) (PSI) (Ball) (PSI) Volts
(in)
±0.005
(ipm) (in) (sec) (in)
3/8 0.375 20 80 90 5 55 155 0.160 95 0.300 0.0 0.110
1/2 0.500 20 80 90 5 55 156 0.160 85 0.300 0.4 0.115
5/8 0.625 20 80 90 5 55 158 0.180 65 0.300 0.5 0.122
3/4 0.750 20 80 90 5 55 163 0.200 50 0.300 0.7 0.133
7/8 0.875 20 80 90 5 55 177 0.250 40 0.400 0.9 0.149
1 1.000 20 80 90 5 55 183 0.300 35 0.450 1.0 0.148
1 1/4 1.250 20 80 90 5 55 185 0.300 20 0.176
1 1/2 1.500 20 80 90 5 55 200 0.350 10 0.211
1 3/4 1.750 20 80 90 5 55 207 0.350 8 0.216
(Bar) (Ball) (Bar) (Ball) (Bar) Volts
(mm)
±0.1
( mm/min)
(mm) (sec) (mm)
1.4 80 6.3 5 3.8 155 4.1 2400 7.6 0.0 2.8
1.4 80 6.3 5 3.8 156 4.1 2000 7.6 0.4 2.9
1.4 80 6.3 5 3.8 157 4.4 1550 7.6 0.5 3.1
1.4 80 6.3 5 3.8 165 5.1 1100 7.6 0.7 3.4
1.4 80 6.3 5 3.8 183 7.6 900 11.4 0.9 3.7
1.4 80 6.3 5 3.8 185 7.6 500 4.5
1.4 80 6.3 5 3.8 200 8.9 250 5.4
1.4 80 6.3 5 3.8 206 8.9 200 5.5
(PSI) /
(Bar)
(Ball)
(PSI) /
(Bar)
(Ball)
(PSI) /
(Bar)
Vo l ts
in ±0.005 /
mm ±0 .1
ipm /
mm/min
in ±0.005 /
mm ±0 .1
(sec)
15 60 80 0.120 300 0.120
1.0 4.1 5.5 3.0 7600 3.0
140 0
Plasma (N
2
) Shield (N
2
)
80 NA
Marking
20A Arc Current
Pre Flow
Pressure
(N
2
)
Cut Flow Rates /
Pressures Arc
Voltage
Torch
Working
Height
Travel
Speed
Initial
Transfer
Height
Pierce
Delay
Marki n g
quality
degrades
as
thickness
decreases
Plasma Gas
Distributor
Electrode Cartridge
Shield
Retainer
Shield Cap
Shield Gas
Distributor
Tip
22-1043 22-1089 22-102222-1015 22-1049 22-1284 22-1067
Material
Thickness
Pre Flow
Pressure
(N
2
)
Cut Flow Rates /
Pressures Arc
Voltage
Kerf Width
@ Rec.
Speed
Plasma (N
2
)
Shield
(H
2
O)*
Edge Start
Torch
Working
Height
Travel
Speed
Initial
Piercing
Height
Pierce
Delay
Kerf Width
@ Rec.
SpeedPlasma (N
2
)
Shield
(H
2
O)*
(mm)
Material
Thickness
Pre Flow
Pressure
(N
2
)
Cut Flow Rates /
Pressures Arc
Voltage
Torch
Working
Height
Travel
Speed
Edge Start
Edge Start
Edge Start
10
12
15
20
Edge Start
Initial
Piercing
Height
Pierce
Delay
* Pressure of the water supply line should be regulated by customer pressure regulator.
Note1:
Ohmic height sensing is not recommended with water shield. Water on the plate interferes electrically with the
ohmic sensing circuit.
Note2:
Water source used for shield must be demineralized.
Stainless Steel
200A
N
2
Plasma / H
2
O Shield
BOLD TYPE
indicates maximum piercing parameters.
BOLD ITALIC
indicates edge starts only.
Requires CCM version 3.4 or later. Requires GCM version 3.2 or later.
44
Edge Start
25
32
38
Cartridge
Electrode
Shield
Shield Gas
Distributor
Tip
Plasma Gas
Distributor
Shield Retainer
Art # A-07917_AC
This Art Is For Reference ONLY