TORCH DATA for Ultra-Cut 8-50 Manual 0-4829 Rev AN
(ga) (in) inch (PSI) (Ball) (PSI) (Ball) (PSI) Volts
(in)
±0.005
(ipm) (in) (sec) (in)
1/2 0.500 20 100 90 5 55 168 0.250 110 0.300 0.3 0.120
5/8 0.625 20 80 100 5 55 170 0.300 105 0.350 0.5 0.126
3/4 0.750 20 80 100 5 55 175 0.300 90 0.350 0.6 0.127
7/8 0.875 20 80 100 5 55 180 0.300 75 0.350 0.8 0.133
1 1.000 20 80 100 5 55 194 0.350 50 0.400 1.0 0.144
1 1/4 1.250 20 80 100 5 55 208 0.400 25 0.450 2.0 0.180
1 1/2 1.500 20 80 100 5 55 210 0.400 20 0.500 3.000 0.197
1 3/4 1.750 20 80 100 5 55 212 0.400 18 0.201
2 2.000 20 80 100 5 55 215 0.400 12 0.204
(Bar) (Ball) (Bar) (Ball) (Bar) Volts
(mm)
±0.1
( mm/min )
(mm) (sec) (mm)
1.4 100 6.3 5 3.8 167 6.3 2900 7.6 0.3 3.0
1.4 80 6.9 5 3.8 170 7.5 2700 8.9 0.5 3.2
1.4 80 6.9 5 3.8 176 7.5 2200 8.9 0.6 3.3
1.4 80 6.9 5 3.8 194 8.9 1300 10.2 1.0 3.6
1.4 80 6.9 5 3.8 208 10.2 630 11.4 2.0 4.6
1.4 80 6.9 5 3.8 210 10.2 500 12.7 3.0 5.0
1.4 80 6.9 5 3.8 212 10.2 460 5.1
1.4 80 6.9 5 3.8 215 10.2 300 5.2
(PSI) /
(Bar)
(Ball)
(PSI) /
(Bar)
(Ball)
(PSI) /
(Bar)
Volts
in ±0.005 /
mm ±0. 1
ipm /
mm/min
in ±0.005 /
mm ±0. 1
(sec)
15 60 80 0.120 300 0.120
1.0 4.1 5.5 3.0 7600 3.0
140 0
Plasma (N
2
) Shield (N
2
)
80 NA
Marking
20A Arc Current
Pre Flow
Pressure
(N
2
)
Cut Flow Rates /
Pressures Arc
Vo l ta ge
Torch
Working
Height
Travel
Speed
Initial
Transfer
Height
Pierce
Delay
Marking
quality
degrades
as
thickness
decreases
Plasma Gas
Distributor
Electrode Cartridge
Shield
Retainer
Shield Cap
Shield Gas
Distributor
Tip
22-1043 22-1089 22-102222-1015 22-1049 22-1284 22-1067
Materi al
Thickness
Pre Flow
Pressure
(N
2
)
Cut Flow Rates /
Pressures Arc
Vo l ta ge
Kerf Width
@ Rec.
Speed
Plasma (N
2
)
Shield
(H
2
O)*
Edge Start
Torch
Working
Height
Travel
Speed
Initial
Piercing
Height
Pierce
Delay
Edge Start
Materi al
Thickness
Pre Flow
Pressure
(N
2
)
C
ut Flow Rates
/
Pressures
Arc
Vo l ta ge
Torch
Working
Height
Travel
Speed
Initial
Piercing
Height
Pierce
Delay
Kerf Width
@ Rec.
Speed
Plasma (N
2
)
Shield
(H
2
O)*
(mm)
Edge Start
12
15
20
25
* Pressure of the water supply line should be regulated by customer pressure regulator.
Note1:
Ohmic height sensing is not recommended with water shield. Water on the plate interferes electrically with the
ohmic sensing circuit.
Note2:
Water source used for shield must be demineralized.
Aluminum
200A
N
2
Plasma / H
2
O Shield
BOLD TYPE
indicates maximum piercing parameters.
BOLD ITALIC
indicates edge starts only.
Requires CCM version 3.4 or later. Requires GCM version 3.2 or later.
50
Edge Start
32
38
44
Cartridge
Electrode
Shield
Shield Gas
Distributor
Tip
Plasma Gas
Distributor
Shield Retainer
Art # A-07917_AC
This Art Is For Reference ONLY