6. Testing requirements 测试要求
6.1 Battery test environment 电池试验环境
Temperature 温度:20±5℃
Relative humidity 相对湿度: 45~85% RH
Atmospheric pressure 大气压力: 86~106 kPa
6.2 Measuring instrumentation requirements 测量仪表要求
Voltage instrumentation requirements: Measuring the voltage meter accuracy no less than 0.5
magnitude
电压仪表要求:测量电压的仪表的精确度不低于 0.5 级
Current instrumentation requirements: Measuring the current meter accuracy no less than 0.5
magnitude
电流仪表要求:测量电流的仪表精确度不低于 0.5 级
Time instrumentation requirements: Measuring the time meter accuracy no less than 0.1%
时间仪表要求:测量时间的仪表精确度不低于 0.1%
Temperature instrumentation requirements: Measuring the temperature meter accuracy no less
than 0.5 ℃
温度仪表要求:测量温度的仪表准确度不低于 0.5℃
Impedance instrumentation requirements: Measuring impedance should by sinusoidal alternating
(1 KHZ) test
内阻仪表要求:测量内阻应由正弦交变(1KHZ)进行测试
7.Operation temperature and humidity range 运行温湿度范围
7.1 Charging temperature 充电环境温度:
0℃ ~ +45℃,Maximum relative humidity:90%
0℃ ~ +45℃,最大相对湿度:90%
7.2 Discharge temperature 放电环境温度:
-20℃ ~ +60℃,Maximum relative humidity:90%
-20℃ ~ +60℃,最大相对湿度:90%
8.Storage temperature and humidity range 存储温湿度范围
8.1 Three months 三个月内:
-20 ℃ ~ + 40 ℃, humidity 45 to 85%
-20℃ ~ +40℃,湿度 45 ~ 85%
8.2 Six months 六个月内:
-20 ℃ ~ + 35 ℃, humidity 45 to 85%
-20℃ ~ +35℃,湿度 45 ~ 85%
8.3 Long-term storage 长期存储:
+20℃ ~ +35 ℃, humidity 45 to 85%
+20℃ ~ +35℃,湿度 45 ~ 85%