Installation Instructions

MODELS: TEVH-36, TEVH-48
Indoor/Outdoor Ventilation Hoods
=
PLEASE READ ENTIRE INSTRUCTION BEFORE PROCEEDING.
INSTALLATIONS MUST COMPLY WITH ALL LOCAL CODES.
IMPORTANT:
Save these Instructions for the Local Electrical Inspector's use.
INSTALLER: Please leave these Installation Instructions with this unit for owner.
OWNER: Please retain these Instructions for future reference
IMPORTANT SAFETY INSTRUCTIONS
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS,
HOODS SHOULD BE INSTALLED WITH VENTILATORS APPROVED FOR USE WITH THE HOOD.
SEE TABLE – 1 OF THIS INSTRUCTION FOR APPROVED VENTILATORS.
WARNING - TO REDUCE THE
RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO
PERSONS, OBSERVE THE
FOLLOWING:
A. Installation work and electrical
wiring must be done by qualified
person(s) in accordance with all
applicable codes & standards including
fire-rated construction. WARNING: to
reduce the risk of fire, use only metal
duct work.
B. Sufficient air is needed for proper
combustion and exhausting of gases
through the flue (chimney) of fuel
burning equipment to prevent
backdrafting. Follow the heating
equipment manufactures guideline and
safety standard such as those published
by the National Fire Protection
Association (NFPA) and the American
Society for Heating, Refrigeration and
Air Conditioning Engineers
(ASHRAE),
and the local code authorities.
C. When cutting or drilling into wall or
ceiling, do not damage electrical wiring
and other hidden utilities.
D. Before servicing or cleaning unit,
switch power off at service panel and lock
service disconnecting means to prevent
power from being switched on
accidentally. When the service
disconnecting means cannot be locked,
securely fasten a prominent warning
device, such as a tag, to the service panel.
CAUTION - TO REDUCE THE RISK OF FIRE AND TO PROPERLY EXHAUST AIR, BE SURE TO
DUCT AIR OUTSIDE FOR DUCTED FANS – DO NOT VENT EXHAUST AIR INTO SPACE WITHIN
WALLS OR CEILING OR INTO ATTICS, CRAWL SPACES OR GARAGES.
Read this instruction completely before starting installation. Planning the complete installation before starting any work is
highly recommended. This includes all aspects of the installation including hood location, ducting, electrical requirements,
and adequacy of mounting surfaces.
DUCTING: Use a minimum 8" round duct for TEVI-060I installations. Use a minimum 10" round duct for TEVI-120I and
TEVE-150E. Use #10100 8" - round transition or #10287 10"-round transition from hood to ducting. Other Transition options
are available – See your Dealer for details.
INSTALLATION INSTRUCTIONS
TABLE - 1
Use model TEVI-060I for internal
ventilator on 36” and 48” hoods.
Use model TEVI-120I for internal
ventilator on 48” hoods only.
Use TEVE-150E for remote
ventilator on 36” and 48” hoods.
This hood has been designed to be used with the ventilators shown in Table-1.
Before cutting into cabinets, it is necessary to confirm that the correct ventilator
is being used. Your dealer should have reviewed your needs prior to your
purchase. Be sure you have the correct ventilation system.
CAUTION: to reduce the risk of fire and electrical shock, install this ventilation
hood onl
y
with blowers s
p
ecified b
y
Twin Ea
g
les.