Table 1: Configuration options
Option
Action
Alarm LED
Define whether the alarm LED indication will be activated.
Optional settings:
LED ON
(default) and
LED OFF
.
Event counter
Define whether an alarm will be activated upon continued
motion (low sensitivity) or upon a single alarm event (high
sensitivity).
Optional settings: LOW sensitivity (default) and HIGH
sensitivity.
Disarm activity
Define whether the device is active when the system is
disarmed.
Optional settings:
NOT Active
while disarmed (default),
no
delay, 5 s delay, 15 s delay, 30 s delay, 1 min delay, 2 min
delay, 5 min delay, 10 min delay, 20 min delay and 60 min
delay.
VERY HOT > 35°C [>95°F]
Note:
Feature not eval-
uated by UL/ULC
Define whether or not the control panel will report a very
hot alert when the temperature rises above the threshold
value for at least the
Alert Delay
duration value. Alert restore
will occur when the temperature drops 1°C (1.8°F) below the
threshold for at least the
Restore Delay
duration.
Note:
The default threshold value for very hot is 35°C
(95°F).
Optional settings: See Configuring the Temperature Alerts.
COLD < 19°C [<66°F]
Define whether or not the control panel reports a cold alert
when the temperature drops below the threshold value for at
least the
Alert Delay
duration. Alert restore occurs when the
temperature rises 1°C (1.8°F) above the threshold for at least
the
Restore Delay
duration.
Note:
The default threshold value for cold is 19°C (66°F).
Optional settings: See Configuring the Temperature Alerts.