User Manual

Preliminary 2003-11-21
DUAL ANTENNA SCANMAX PRO DEACTIVATOR CONTROLLER 8200-0365-01, REV. 1A
INSTALLATION AND SERVICE GUIDE
12 of 12
Specifications
The input voltage to the power supply shall be 90–
264 VAC, 50 or 60 Hz ±5%. AC line current shall
not exceed 2 amps rms. The power supply output
to the controller must be 22Vdc +5%. Sensormatic
power supply 606-0049-01 is specified for this
application.
Electrical
Voltage input
to power supply ........................... 90–264Vac,
50/60Hz (±5%)
Voltage input
from power supply ....................... 22Vdc
AC line current............................. 2Arms
Environmental
Operating temperature................. 0 to 40°C
(32° to 104°F)
Non-operating temperature.......... –40° to 70°C
(–40° to 158°F)
Relative humidity ......................... 0 to 90%
non-condensing
Mechanical
Height .......................................... 10cm (3.9in)
Width ........................................... 26.3cm (10.4in)
Depth ........................................... 22.1cm (8.7in)
Weight ......................................... 2.5kg (5.5 lbs)
Declarations
Regulatory Compliance
EMC ............................................... 47 CFR, Part 15
RSS 210
EN 300 330
EN 301 489
Safety....................................................... UL 60950
CSA C22.2 No 60950
EN 60950
FCC COMPLIANCE: This equipment complies with Part 15
of the FCC rules for intentional radiators and Class A digital
devices when installed and used in accordance with the
instruction manual. Following these rules provides reasonable
protection against harmful interference from equipment
operated in a commercial area. This equipment should not be
installed in a residential area as it can radiate radio frequency
energy that could interfere with radio communications, a
situation the user would have to fix at their own expense.
EQUIPMENT MODIFICATION CAUTION: Equipment
changes or modifications not expressly approved by
Sensormatic Electronics Corporation, the party responsible for
FCC compliance, could void the user's authority to operate the
equipment and could create a hazardous condition.
Other Declarations
WARRANTY DISCLAIMER: Sensormatic Electronics
Corporation makes no representation or warranty with respect
to the contents hereof and specifically disclaims any implied
warranties of merchantability or fitness for any particular
purpose. Further, Sensormatic Electronics Corporation
reserves the right to revise this publication and make changes
from time to time in the content hereof without obligation of
Sensormatic Electronics Corporation to notify any person of
such revision or changes.
LIMITED RIGHTS NOTICE: For units of the Department
of Defense, all documentation and manuals were developed at
private expense and no part of it was developed using
Government Funds. The restrictions governing the use and
disclosure of technical data marked with this legend are set
forth in the definition of “limited rights” in paragraph (a) (15)
of the clause of DFARS 252.227.7013. Unpublished - rights
reserved under the Copyright Laws of the United States.
TRADEMARK NOTICE: ScanMax and Sensormatic are
registered trademarks of Sensormatic Electronics Corporation.
Other product names mentioned herein may be trademarks or
registered trademarks of Sensormatic or other companies.
No part of this guide may be reproduced in any form without
written permission from Sensormatic Electronics Corporation.
MDR 11/03