User's Manual

AMS-1080 DETECTION SYSTEM 8200-0418-01, REV. A
INSTALLATION AND SERVICE GUIDE
17 of 18
Fuse Replacement
The controller has two 2A, 250V slow-blow fuses in
the IE320 ac receptacle.
1. Pry the rectangular cover plate from the ac
receptacle using a small slotted screwdriver.
Two spring-loaded fuses should pop out.
2. Replace the blown fuse (or fuses) with 2A,
250V slow-blow fuses (P/N 5111-0028-07).
Specifications
Electrical
POWER SUPPLY
Primary input............................ 100-120Vac or
200-240Vac @ 50–60Hz
Primary power fuse .................. 2A, 250V, slo-blow,
hi-breaking
Current draw ............................ <1.0Arms @ 120Vac
Input power .............................. <100W
TRANSMITTER
Operating frequency................. 58kHz (±200Hz)
Transmit burst duration ............ 1.6ms
Transmit current maximum ...... 15A peak
Burst Repetition Rate:
Based on 50Hz ac.................... 75Hz or 37.5Hz
Based on 60Hz ac.................... 90Hz or 45Hz
RECEIVER
Center frequency...................... 58kHz
Environmental
Ambient temperature................ 0°C to 50°C
(32°F to 122°F)
Relative humidity...................... 0 to 90%
non-condensing
Mechanical (AMS-1080 Controller)
Length ...................................... 37.3cm (14.7in)
Width........................................ 27.8cm (10.9in)
Height....................................... 13.4cm (5.3in)
Weight...................................... 3.33kg (7.34 lbs.)
Mechanical (AMS-1080 Antenna)
Thickness................................. 3.6cm (1.4in)
Width........................................ 36.4cm (14.3in)
Height....................................... 121.3cm (47.8in)
Weight...................................... 5.2kg (11.5 lbs.)
Fuses (2)