Install Guide
Table Of Contents
- AMS-9030 Controller
- _
- About this Guide
- Controller Overview
- Installation Requirements
- Mounting the Controller
- Connecting Antennas
- Connecting Remote Alarms
- Connecting External Devices to Controller Relays
- Connecting Noise Canceling Antennas
- Connecting Multiple 9030 Controllers
- Connecting a Service Laptop
- Connecting a SyncLink Device
- Connecting an Ultra*Link Device
- Connecting Power to the Controller
- Specifications
- Declarations
Preliminary
AMS-9030 CONTROLLER 8200-0344-02, REV. 0
INSTALLATION GUIDE
14 of 16
Figure 11. Wired sync wiring diagram
1
2
3
1
2
3
5. Use the configurator to set the Advanced
Settings parameters in the controllers to the
following values.
Wired synchronization Advanced Settings
parameters
Parameter Master Slave
Wired Sync Enable
Enabled Enabled
Wired Sync Master
Enabled Disabled
6. Check the status LED on the slave controllers.
If the LED is flashing amber twice as fast as
normal (two times per second), then the slave is
not receiving a synchronization signal and you
must recheck the installation or the software
setup.
Connecting a Service
Laptop
To use the configurator on your service laptop to
configure the controller, connect your laptop to the
female RJ22 port labeled “Service” on the
controller. See Figure 7.
You can also connect a service laptop remotely
over a network. For information on connecting a
laptop remotely, refer to the Setup and Service
Guide.
In addition to the controller, some antennas have a
service port to which you can connect a service
laptop.
Figure 12. Connecting a local service laptop
Connecting a SyncLink
Device
SyncLink devices connect to the controller at the
SyncLink port on the controller. The location and
pinout of the SyncLink port is shown in Figure 7.
Sync signal
Ground
Shield
P9
P9
Master Controller
Slave Controller
Sync signal
Ground
Shield
RJ22 male connector
RJ11 male
connecto
r
RJ11 male to RJ22
male cable
DB-9-to-RJ11
adapter
laptop DB-9 serial port
service port (RJ22 female)