Install Guide
Table Of Contents
- AMS-9030 Controller
- _
- About this Guide
- Controller Overview
- Installation Requirements
- Mounting the Controller
- Connecting Antennas
- Connecting Remote Alarms
- Connecting External Devices to Controller Relays
- Connecting Noise Canceling Antennas
- Connecting Multiple 9030 Controllers
- Connecting a Service Laptop
- Connecting a SyncLink Device
- Connecting an Ultra*Link Device
- Connecting Power to the Controller
- Specifications
- Declarations
Preliminary
AMS-9030 CONTROLLER 8200-0344-02, REV. 0
INSTALLATION GUIDE
15 of 16
Connecting an Ultra*Link
Device
Ultra*Link devices are connected to the controller
at the Service port on the controller and at the
COMM1 port on the Ultra*Link device. The location
and pinout of the Service port is shown in Figure 1.
Note: if the controller has an Ultra*Link device on
its Service port, it cannot communicate with a
laptop connected there or on an antenna.
Connecting Power to the
Controller
The standard controller receives power through a
power cord that is plugged into the IEC320
connector shown in Figure 7.
One power switching options is available for the
controller: a keyswitch option. This option must be
hardwired to a power source. Refer to the
installation manual for this option for more
information.
After connecting the controller to ac power, check
the status light (Figure 7) to make sure it is flashing
green once a second. If it is flashing two times a
second or it is red, it indicates a problem with the
system.
WARNING: RISK OF ELECTRIC
SHOCK! Ensure power is turned off at
circuit breaker before hardwiring
controller.
Specifications
Electrical
Power Supply
Primary Input .................................... 100-130Vac or
200-240Vac
@ 50–60Hz
Primary Power Fuse............................... 2.5A, 250V
Current Draw ............................1.2A peak (120Vac)
0.8A peak (230Vac)
Input Power .................................................. <150W
Transmitter
Outputs................................. 2 ports (two antennas,
multiplexed)
Operating Frequency .....................58kHz (±200Hz)
Transmit Burst Duration .................................1.6ms
Transmit Current ........................................ 8A peak
Burst Repetition Rate:
Based on 50Hz ac ................. 37.5Hz (Normal)
75Hz (Validation)
Based on 60Hz ac .................... 45Hz (Normal)
90Hz (Validation)
Receiver
Inputs.................................... 2 ports (two antennas,
multiplexed)
Center Frequency ..........................................58kHz
Alarm
Alarm Relay Output ......................... DPDT contacts
Contact Switching Current ...................... 1.0A max.
Contact Switching Voltage ....................... 28V max.
Lamp/Audio Duration ............................... 1–30 sec.
(1 sec. increments)
Environmental
Operating Temperature:...0° to 50°C (32° to 122°F)
(32° to 122°F)
Non-operating Temperature................. -40° to 70°C
(-40° to 158°F)
Relative Humidity: ........... 0 to 90% non-condensing