Install Guide

Preliminary
AMS-9030 CONTROLLER 8200-0344-02, REV. 0
INSTALLATION GUIDE
2 of 16
Controller Overview
An AMS-9030 controller is part of an Ultra•Max
®
security label detector. The controller supports the
following system components, some of which are
shown in Figure 1:
Two transceiver antennas or two pairs of Tx/Rx
antennas for tag and label detection.
One remote alarm (optional), but the controller
supports two-alarm configurations with two
internal relays.
Two noise canceling antenna kits to reduce the
effect of electro-magnetic interference
(optional).
Four external devices, such as cameras,
activated by two relays in the controller
(optional).
A service laptop for configuration and trouble-
shooting.
A SyncLink transmitter to synchronize the
detectors with deactivators at the site
(optional).
An Ultra*Link device (optional).
An RS-485 network (optional). This manual
only describes how to connect a controller to
an RS-485 network. For information on setting
up an RS-485 network, refer to the AMS-9030
Setup and Service Guide.
Figure 1. AMS-9030 system components
Installation Requirements
Verifying Equipment and Unpacking
Verify that all equipment has arrived. Make sure
the system configuration is the right one for the
installation site.
Unpack major components in a back room. At
the install site, lay out parts in the order you will
need them. Do not clutter the aisle or cause a
trip hazard.
Installer/Contractor
Shall have electrical work comply with the latest
national electrical code, national fire code, and
all applicable local codes and ordinances.
Shall coordinate all work with other trades to
avoid interference.
Shall verify existing site conditions and
coordinate with the owner’s representative and
appropriate utilities as required.
Shall obtain copies of all related plans,
specifications, shop drawings and addenda to
schedule and coordinate related work.
Shall thoroughly review the project to ensure
that all work meets or exceeds the above
requirements. Any alleged discrepancies shall
be brought to the attention of your local
Technical Support representative.
WARNING: Do not install this product in
hazardous areas where highly
combustible or explosive products are
stored or used.
Electrical and Site Requirements
G The controller connects to a 100-130Vac or
200-240Vac source. No fuse exchange is
required for the controller.
G The ac source must be unswitched with less
than 0.5Vac between neutral and ground.
G DO NOT share the ac source with neon signs,
motors, computers, cash registers, terminals,
or data communications equipment.
G DO NOT use orange-colored outlets dedicated
for computer equipment.
Antennas
Remote alarm (optional)
AMS-9030 controller