AC Hookup
Ac power connects to the controller using a power
cord or hardwired cable.
The power source can be 100-120Vac
or 200-240Vac.
The controller automatically senses the voltage
so no jumper settings are required.
WARNING—RISK OF ELECTRIC
SHOCK! The ac power cord may carry
120Vac or 240Vac.
CAUTION: When using a power cord, a
socket-outlet must be installed near the
controller and in an easily accessible
location.
Für Installationen mit einem Stromkabel muß
die Steckdose an einem Standort installiert
werden, welcher einfachen Zugang erlaubt.
CAUTION: A 10A, 2-pole, ganged
disconnect device, which also provides
short circuit and overload protection, and
has a minimum 3mm open circuit
clearance, in accordance with the
National Electric Code and applicable
local codes must be installed by a
licensed electrician at a location readily
accessible to the equipment.
Ein 10A, 2-poliges, gekoppeltes
Ausschaltgerät, welches auch über einen
Kurzschluß- sowie Überbelastungsschutz
verfügt, und einen minimum 3mm offenen
Schaltabstand aufweist, nach
Übereinstimmung mit den Nationalen
Elektrischen Regelungen sowie lokalen
Regeln, muß an einem Standort installiert
werden, welcher einfachen Zugang zum
Gerät erlaubt.
Power Cord
Referring to the figure below:
1. Choose a power cord for the country of use.
Power cords come in .9m (3ft), 2.7m (9ft), 3.7m
(12ft), and 4.6m (15ft) lengths.
2. Route the power cord through the slot in the
cable tray.
CAUTION: DO NOT remove the three
knockouts used to access the ac
connection area.
CAUTION: DO NOT use the plug
intended for hardwiring.
3. Apply strain relief to the power cord according to
the country of use. For USA and Europe, use a
white cable clamp on both the inside and
outside of the cable tray.
Outside
Inside
For Japan, use a black cable clamp only on the
outside of the tray.
AMS-9040 CONTROLLER 8200-0367-02, REV. D
INSTALLATION AND SERVICE GUIDE
12 of 22