User's Manual
Table Of Contents
- AMS-9040 Controller
- Contents
- To the Installer
- About the Product
- Basic Operation and Setup
- Device Connections
- Transceiver (Tx/Rx) Antenna and Antenna Communication Connections
- General-Purpose Auxiliary Connections (P27, P29, P31, P33)
- Remote Alarm Connections (P7)
- Beacon Lamp Connections (P10)
- Relay Connections (P9, P12)
- Alarm Management Connection (P41)
- RS-485 Connection (P8)
- Wired Tx Sync Connection (P2)
- Wireless AC Sync Connection (On Controller)
- RS-232 Service Connection (On Controller)
- Ped (Tx) Inhibit Connection (P26)
- Installation Features
- Service Features
- Installation Requirements
- Installation Procedure
- AC Hookup
- System Setup
- Redistributing the Load
- Special Rules for Floor Antennas
- Troubleshooting
- Fuse Replacement
- Specifications
- Declarations
- Appendix A: Auto Synchronization
AMS-9040 CONTROLLER 8200-0367-02, REV. D
INSTALLATION AND SERVICE GUIDE
18 of 22
Controller-Assisted Tuning
cannot be Performed
If controller-assisted tuning cannot be performed, a
message indicating the cause is posted on the
service configurator. Instances the software
recognizes are:
• Tx set to off in the service configurator
• Tx inhibit active
• Auto line delay not ready
• Key switch turned to off (locked).
Another possible cause of controller-assisted
tuning failures is a mismatch between the address
switch on the antenna cap board and the antenna
connector on the AMS-9040 (for example, setting
the address switch on the antenna cap board to 3
when the antenna Tx/Rx cable is connected to the
first connector). Controller-assisted tuning will not
work but no error message will be displayed.
Once the CE has turned the transmitter on,
controller-assisted tuning can be performed.
Local Diagnostics
You can troubleshoot and change controller
parameters using your laptop computer and
AMS-9040 service configurator software.
The following hardware is required:
• Service cable with a male RJ-10/22 phone
connector on one end and a male RJ-11/12
connector on the other
• DB-9-to-RJ-11/12 connector.
How to Connect Cables
1. Connect the DB-9-to-RJ-11/12 connector to the
DB-9 serial port on your laptop computer. Only
pins 2, 3, and 5 are used.
2. Connect the RJ-11/12 connector of the service
cable to the DB-9 connector and the RJ-10/22
connector on its other end to the RS-232
service port (RJ-10/22) on the controller.
DB-9
RJ-11/12
RJ-10/22 to
RS-232 port on
controller