User's Manual
Table Of Contents
- AMS-9050 Controller
- Contents
- To the Installer
- About the Product
- Installation Features
- Setup Features
- Service Features
- Basic Operation and Setup
- Device Connections
- Installation Features
- Service Features
- - The service configurator displays the operating current for each antenna. Operating current is 15A peak for all countries.
- - The service configurator displays ambient temperature within the controller.
- - The hardware supports software with a remote command to reset the system.
- - Hardware within the controller protects it from runaway software.
- Installation Requirements
- Controller Installation
- Troubleshooting
- Fuse Replacement
- Specifications
- Declarations
- AMC-7000 Integrated Metal Foil Detection
- About this Guide
- About the Product
- Installation
- Specifications
- Declarations
Preliminary
System Setup
1. Ensure controller power is off.
2. Connect antenna cables to the controller
according to how the antennas are intended to
perform. Refer to diagrams and tables on pages
3 and 4 of this guide. See examples of pedestal
installations in the antenna installation guide.
3. Set DIP switches S1 and S2 in the controller for
the pedestal type, number of pedestals, and the
antenna configuration used (see page 5).
4. Turn on the laptop computer and launch the
ADS 4 service configurator.
Note: For instructions on how to use configurator
settings, click Help on the configurator.
IMPORTANT! Ensure the controller power is off.
Never restart or boot up a computer connected to
an active controller. Doing so disables the mouse
function on the computer.
5. Turn on the controller and connect the laptop
computer to the service port.
6. Using the “Setup” page on the configurator:
a. Check that antenna selections match
antennas physically installed. If not, check
antenna connections to the controller.
b. Setup parameters for lamps, audio, relays,
and remote alarms.
7. Using the “Tx Configuration” page, set Tx
current for each antenna and enable/disable
transmitters, if necessary.
8. Pass an active security tag by each antenna to
verify antenna performance. Refer to Help if
monitoring or adjustments are necessary.
Verifying Operation
Check that the antenna alarm lamp lights when a
tag/label is passed through the checkout aisle, or if
the system is covering adjacent aisles, that the
lamp lights only in the aisle the tag/label was in.
If the pick rate is acceptable, installation is
complete. Reattach the top cover.
AMC-7000 INTEGRATED METAL Foil DETECTION 8200-2609-01, REV. 3a
INSTALLATION GUIDE