User's Manual

Table Of Contents
Preliminary
Wiring the AMS-9050 Controller
Connect the following cables to the AMS-9050
controller. Refer to Figure 1and Figure 2.
Connector Cable P/N and Name
P92
(Ant A Alarms)
0652-0243-01 (AMS-9050 Com)
from P5 on Antenna A
P58
(Ant A Tx)
0652-0467-02 (AMC-7000 Tx/Rx)
from P1 on AMC-7000
P97 or P100
1
(Ant B/D Alarms)
0652-0468-01 (AMC-7000 Power)
from P8 on AMC-7000
P63 or P64
(Remote Alarm)
0652-0468-01 (AMC-7000 Power)
from P14 on AMC-7000
P2
2
Wired Sync
0652-0467-01 (AMC-7000 Wired
Sync) from P5 on AMC-7000
P88
Ant C Tx
0652-0467-02 (AMC-7000 Tx/Rx)
from P3 on AMC-7000
P93
Ant C Alarms
0652-0243-01 (AMS-9050 Com)
from P5 on Antenna C
1 The eight-pin Alarm/comm connector is supplied to connect
the AMC-7000 Power and AMC-7000 Com cables to P97 or
P100 on the AMS-9050. The AMS-9050 controller should
already have this connector, so this connector should not be
needed.
2 Use one of the two five-pin Aux/Wired Sync connectors to
connect the wired sync cable to P2 on the AMS-9050.
Connecting Relay-activated
Devices
The Metal Foil Detection enclosure can connect to
relay-activated devices such as camera switchers
or pager systems. You can then program the
device to perform some function, such as switching
cameras or sending a message to a pager. These
devices are connected to P9 on the Metal
Detection Board.
Two relays are available on P9: Relay A (1) and
Relay B (2). (Refer to Figure 2 for a pinout of P9.)
Both of these relays are activated for one second
when a metal event is detected. These relays are
not configurable. If additional relays are needed,
you can use the relays on the AMS-9050 controller;
they are configurable on the Setup screen of the
ADS4 Platform configurator. Refer to “Configuring
the Alarm Settings” on page 29 for more
information.
AMC-7000 INTEGRATED METAL Foil DETECTION 8200-2609-01, REV. 3a
INSTALLATION GUIDE
19 OF 31