User's Manual

Table Of Contents
Preliminary
Mounting the AMC-7000
3. Mount the AMS-9050 to the wall or ceiling. See
Figure 5.
The controller has a built-in flange used to
attach the controller to a wall or ceiling using
suitable hardware. Because the metal foil
detection box mounts to the AMS-9050
controller, the controller must be mounted to the
wall or ceiling securely enough to support four
times the combined weight of the controller
(6.5kg) and metal foil detection box (2.4kg).
Therefore, the mounting method must support
35.4kg (79lbs).
The AMC-7000 enclosure can be mounted either
on top of the AMS-9050 controller or next to it.
Mounting next to the controller
The AMC-7000 enclosure can be mounted next to
the controller. See Figure 4.
To ensure the cables can reach from the
enclosure to the controller, do not mount the
enclosure more than 15cm (6in) from the
controller.
Drywall attachment – Use four 23kg (50lb)
drywall anchors and four #8 screws at least
32mm (1-1/4in) long or their equivalents to
attach the AMS-9050/AMC-7000 combo to
the drywall.
Ensure the enclosure is mounted in the
same orientation as shown in Figure 4 so
that the cables will be able to reach the
connectors in the controller.
Ceiling attachment – Use a sheet of 16mm
(5/8in) plywood and four #8 screws at least
32mm (1-1/4in) long to attach the controller
to the plywood.
Mounting on top of the controller
1. Attach the two mounting brackets to the top of
the AMS-9050 controller.
2. Attach the AMC-7000 enclosure to the two
mounting brackets. Ensure the enclosure is
oriented correctly relative to the controller, as
shown in Figure 4.
Figure 4. Mounting the AMC-7000 next to an AMS-9050 controller
15cm (6in)
max. separation
(due to cable
lengths)
screw
Ensure the AMC-7000 enclosure is
oriented in relation to the AMC-7000
as shown in the figure or some cables
may not reach the controller.
anchor
AMC-7000 INTEGRATED METAL Foil DETECTION 8200-2609-01, REV. 3a
INSTALLATION GUIDE
23 OF 31