Connecting AC Power
The controller can receive AC power either through
a power cord or through a hardwired connection.
CAUTION: A 10A, 2-pole, ganged
disconnect device, which also provides
short circuit and overload protection, and
has a minimum 3mm open circuit
clearance, in accordance with the
National Electric Code and applicable
local codes must be installed by a
licensed electrician at a location readily
accessible to the equipment.
1. Locate the voltage shunt, which is in a bag
taped inside the enclosure.
WARNING: RISK OF ELECTRIC
SHOCK! Ensure that the system is
not powered before moving the
shunts.
2. Select the proper voltage for the site using the
shunt (2109-0062-01) included with the kit. The
default setting is 240Vac.
120 Vac:
J1 shunt IN
240 Vac:
J1 shunt OUT
Power cord connection
1. Choose a power cord for the country of use.
USA-IEC 320, 18/3, 125V, 10A, 7.5ft.
Schuko-IEC 320, 1mm sq., 250V, 10A, 2.5m
UK-IEC 320, 1mm sq., 250V, 10A, 2.5m
Japan-IEC 320, 2mm sq., 250V, 15A, 2.5m
US-Filter, Line, 125V, 6A, Plug-in
Australia to IEC 320, 2.5m, 250V, 10A
WARNINGRISK OF ELECTRIC
SHOCK! The ac power cord may carry
120Vac or 240Vac.
CAUTION: When using a power cord,
a socket-outlet must be installed near
the controller and in an easily
accessible location.
2. Plug the power cord into the IEC320 receptacle
and the power source.
Hardwired connection
CAUTION: Use only copper wire.
WARNINGRISK OF ELECTRIC
SHOCK! The ac power cord may carry
120Vac or 240Vac. Ensure the power
is turned off at the circuit breaker
before performing the following
procedure.
1. Ensure the controller does is not powered and
the hard-wire cables are not powered.
2. Unplug the existing power cable connector
from the main board, loosen the screws
holding the two wires, and pull out the wires.
3. Unscrew the ground lug from the main board.
Save the ground screw.
4. Cut the three wires connecting the IEC320
connector to the wiring harness with the ferrite.
They should be cut as close as possible to the
IEC320 connector.
5. Cut the ferrite from the power cord.
AC IN
(120Vac/
240Vac)
Ferrite
Cut wires here