User's Manual

Preliminary
ULTRA MAX PHASING TOOL 8000-2579-49 REV. B
USER GUIDE
4 of 9
8000-2579-49
If LED 2 is lit system being checked is
within the +/- 50usec window considered to
be in-phase
If LED 3 is lit system being checked is
leading greater than 50usec
Laptop Setup and Use
1. Connect the included Micro-USB to USB-B
cable to the phasing tool. Then connect the
other end to a laptop. If the H3 USB Serial port
driver is already installed, the laptop assigns a
Com port to the phasing tool. To determine
which port was assigned, open the computer
management screen and observe the port list.
The list updates as the port is added. In the
example below, Com port 5 was assigned to
the tool when the cable was plugged in.
To navigate to the Computer Management
screen:
a. Right click Computer on the Start
menu.
b. Select Manage. The Computer
Management window opens.
c. Click on Device Manager. A list of
device types displays.
d. Expand the Ports list to display the
port numbers.
Figure 3. Computer Management Window
Settings
2. PuTTY is used to talk to the tool and the
System Configurator is used to perform the
phase adjustment.
The phasing tool displays the phase delta and
other information on the laptop using PuTTY as the
interface.
1. Install the provided USB driver. This is
included in the ADS4 bundle available on
www.sensormatic.com.
To install the USB driver, perform the following
steps.
a) In windows explorer navigate to your C
drive and select System Properties
from the top menu.
Figure 4.System Properties
b) Select Device Manager and expand
the Ports menu. You see a question
mark icon beside the
Communications Port.
c) Right click and select Update Driver
Software.
d) Select Browse my computer for
driver software.
e) Navigate to C:\Program Files
(x86)\Sensormatic\ADS4 Platform
Software\Release XXXX\Driver.
f) Click the installation file and follow the
wizard to install the driver.
2. Launch PuTTY. It can be downloaded at the
following address.
https://the.earth.li/~sgtatham/putty/latest/x86/p
utty.exe
3. Select Serial Communication and enter the
com port which corresponds to the USB port
that the phase tool is connected to.
4. Enter the Speed manually as 115200.