7. On the side panel of the Test Tool, select the ‘Image’ tab.
Then from the ‘Get’ pull down menu, select ‘Image’. Verify on
the DVR screen that the IVS Device is capturing and
processing the video image.
8. Verify that the image on your display corresponds to the
image “seen” by the IVS device.
9. Select ‘New Line’ from the side panel of the Test Tool. Select
the line color from color palette and click OK.
10. Using the mouse, position the cursor to indicate the start of
the line, drag it to the desired destination point, then click the
cursor again. An arrow indicates the traffic direction.
Dragging the line left to right produces an UP arrow.
Dragging the line right to left produces a DOWN arrow.
Traffic crossing the line in the direction of the arrow would
trigger ‘IN’ counts.
Traffic crossing the line in the direction opposite the arrow
would trigger “OUT’ counts.
11. From the ‘Diag’ pull down menu, select ‘Verification Test’ to
invoke an ‘Open’ dialog box to save the count data to a .txt
file. Name and save file for later retrieval.
Note: A ‘Test In Progress’ indication at the bottom right of the
Test Tool appears as shown below.
12. After the prescribed count intervals, terminate the verification
test by clicking ‘Disconnect’ at the bottom of the Test Tool.
13. Retrieve .txt file for count verification against the DVR
captured events.