User's Manual

Table Of Contents
4-4 8000-2803-01, Rev. 1/A8000-2803-01, Rev. 1/A8000-2803-01, Rev. 1/A8000-2803-01, Rev. 1/A Installation
1. Remove door threshold, and determine if there
is adequate clearance to place connecting wire
under it without cutting a floor trench.
2. If necessary, cut floor trench (0.3cm [1/8in.]
wide by 1.2cm [1/2in.] deep).
3. Locate ends of loop wire tucked into frame at
top and bottom of each antenna.
Note: Remove bottom cap to retrieve wire
loop, feed through opening in cap, and re-
install cap.
4. Cut two pieces of wire to complete wire loop
above and below door/portal (connecting
wires).
5. Run top connecting wire above door/portal and
connect to antenna wire at top of each
antenna.
6. Run bottom connecting wire under doorway.
Conceal by replacing threshold or sealing
trench being careful not to pinch wire.
7. Connect to antenna loop wire at bottom of
each antenna.
The wire loop is installed and ready to operate.
Connect RF Controller Cables
WARNING: RISK OF ELECTRIC
SHOCK! Read manual before
servicing.
1. Connect 8-conductor control cable from RF
controller to terminal block on the RF antenna
board as follows:
Pin Function
Pin 1 RX–
Pin 2 RX+
Pin 3 Red LED
Pin 4 Amber LED
Pin 5 Green LED
Pin 6 LED Ground
Pin 7 TX
Pin 8 N/C
2. Connect terminal block to control connector P2
(pin 1 is at outside edge of board).
3. Connect 2-conductor power cable to terminal
block as follows:
Pin Function
Pin 1 +16Vdc
Pin 2 Return
Pin 3 Unused
Pin 4 Unused
4. Connect terminal block to power connector P1
(pin 1 is at bottom).
Note: See Chapter 5: Service for information
about verifying and optimizing antenna
performance.
1: RX–
2: RX+
3: Green LED
4: Amber LED
5: Red LED
6: LED Ground
7: TX
8: N/C
4: Unused
3: Unused
2: Return
1: Vcc
!
Loop Wire