User's Manual

Table Of Contents
C•CURE Watch Installation and Service Guide 8000-2803-01, Rev. 1/A 4-5
Install Finishing Hardware
1. Insert stabilizing brackets as shown below, one
at top and one at bottom of antenna. Attach to
mounting bracket with two screws.
2. Install antenna top cap.
Place top cap over antenna interface board
starting at front. Position LED window over
LEDs. A pin inside cap front seats in antenna
cover beneath LEDs. Secure at sides with two
screws.
DO NOT leave antenna components exposed
for extended periods.
3. Install raceway to conceal exposed wiring.
Install RF Controller
Installing RF controller includes the following:
Prepare for installation
Mount the RF controller enclosure
Connect RF antenna cables
Connect inputs and outputs
Connect power supply cable
Connect communications cable
Connect sync cable
Prepare for Installation
The following items are required before installation
begins:
Site plan indicating:
Installation site of RF controller
Installation sites of RF antennas and
associated reader addresses
Inputs and outputs associated with
antenna 1 (optional)
Installation site of host panel
Installation site of power supply enclosure
Optional inputs and outputs are to be
connected to antenna 1.
Installation site of common terminal block
for RF controller synchronization.
Two cables (one control and one power) run
between RF antennas and RF controller.
Optional — cable run between each required
input and output and RF controller.
RF Controller Install Kit (0351-2160-01)
Verify contents of kit before beginning installation.
Description Qty. Part No.
Plastic Anchors, 10-12, 1”L, w/scr 4 2880-0098-01
Template, C•CURE Watch RFID Contrlr 1 8000-2820-01
Install and Service Guide 1 8000-2803-01
Mount the RF Controller
Enclosure
1. Remove screws that secure enclosure cover.
Remove cover by pulling forward slightly at top
and slip cover straight up until cover is free of
the retaining tab at bottom of enclosure.
Mounting Bracket
Stabilizing Bracket