User's Manual

Table Of Contents
4-6 8000-2803-01, Rev. 1/A8000-2803-01, Rev. 1/A8000-2803-01, Rev. 1/A8000-2803-01, Rev. 1/A Installation
2. Verify that On/Off switch is in off position.
NL
3. Hold enclosure in its mounting location and
mark position of mounting screws (4) at
openings in back of enclosure.
4. Drill holes for screws and install wall anchors if
required. Insert top screws and tighten until
almost flush with wall.
5. Slip enclosure over screws and slide down to
lock screws in keyhole openings.
6. Tighten top screws. Insert bottom screws and
tighten.
Connect RF Antenna Cables
RF antenna cable connections differ depending on
whether RF proximity or RF passage antennas are
used.
Connecting RF Proximity Antenna Cables
RF proximity antennas are not available at this
time.
Connecting RF Passage Antenna Cables
The following steps must be completed for each
RF antenna connected to this RF controller.
1. Connect 8-conductor control cable from RF
antenna to 9-pin terminal block on RF
controller as follows:
Pin Function
Pin 1 Shield
Pin 2 RX–
Pin 3 RX+
Pin 4 Red LED
Pin 5 Amber LED
Pin 6 Green LED
Pin 7 LED Ground
Pin 8 TX
Pin 9 N/C
2. Connect terminal block to appropriate antenna
control connector (pin one is solid).
NL
Note: The RF controller provides two
channels. One channel is associated with
antenna connectors 1 and 2 and the other
channel is associated with antenna connectors
3 and 4.
Always connect the two antennas that
comprise a pair to the same channel.
Antenna Connector Channel
Antenna 1 First Channel
Antenna 2 First Channel
Antenna 3 Second Channel
Antenna 4 Second Channel
3. Connect 2-conductor power cables from RF
antennas to 4-pin terminal blocks as follows.
Always combine antennas 1 and 2 on one
connector and antennas 3 and 4 on the other.
Pin Function Connector Antenna
Pin 1 Return P24
Pin 2 +16Vdc P23
Antenna 1 or 2
Pin 1 Return P22
Pin 2 +16Vdc P21
Antenna 3 or 4
Antenna 1Antenna 2
Antenna 3
Antenna 4
On/Off Switch
Mounting