User's Manual

Table Of Contents
5-2 8000-2803-01, Rev. 1/A Service
Parts List
Description Product Code
C•CURE Watch RF Controller
with universal power supply CW-RID-1
RF Passage Antenna, Model A CW-ANT-PA
RF Passage Antenna, Model B CW-ANT-PB
C•CURE Watch Programmed Badge CW-FBRW-1
RFID 56 Format
The RFID 56 card format must be selected in the
Card Format window of C•CURE 800/8000. If it is
not an available choice, the following information
should be entered:
Identification
Name: RFID 56
Card Characteristics
Format Usage: Select Access control if this is
an access only installation.
Select Asset tracking if this is
an asset and access or an
asset only installation.
Type: Proximity
Field List
Field Type
Start
Length
Compl.
P. Start
P. Length
Shift
Facility Code 17 16 No 0 0 0
Card Number 33 24 No 0 0 0
Tune RF Passage Antennas
WARNING: RISK OF
ELECTRIC SHOCK! When
powered, high voltage exists on
the antenna board and at
tuning jumpers.
To optimize system performance, each RF
passage antenna must be tuned. The tuning
process uses six tuning jumpers to peak antenna
voltage.
Tuning Guidelines
RF passage antennas located within 4.6m (15ft) of
an antenna being tuned may interfere with the
tuning process (other passage antennas connected
to the same RF controller as antenna being tuned
DO NOT interfere with tuning). Interference is
possible even if antenna is connected to another
system or not connected to any system. Follow
these guidelines to eliminate the possibility of
interference:
If interfering passage antenna can be moved,
place it further than 4.6m (15ft) from antenna
being tuned.
Tuning Procedure
Passage antennas are tuned while they operate. If
you have a partner, multiple antennas can be
tuned at the same time.
1. Turn Off RF controller power switch Off.
WARNING: RISK OF
ELECTRIC SHOCK! When
powered, high voltage exists on
the antenna board and at
tuning jumpers.
2. Verify the following before beginning:
Antennas are completely installed and
connected to RF controller. This includes
wire loop if it is to be used.
Power is available to RF controller.
3. Remove RF passage antenna top cap.
!
!