User's Manual

Preliminary
AMC-4010 SYNCHRONIZATION MODULE INSTALLATION AND SERVICE GUIDE (8200-0183-01, REV. 03)
2 of 5
4. Close the module and reattach the holding
screw.
5. Mount the transmit module:
As high as possible and in a location near
the designated EAS device. The length of
the cable supplied determines the distance
the module can be from the device.
IMPORTANT! Ensure the module will be
within 60.1m (200 feet) of the transmit
module.
In such a way that the two LEDs on the
module can be readily see from below.
Note: It is recommended to mount the
module to an electrical access pole of a
checkout counter by running a tie wrap
through the two key slots on the back of
the module and then running two additional
tie warps through the tie wrap and around
the pole (see box).
Receivers (Rx) must be within
60.1m (200 feet) of the transmitter (Tx)
6. Using the cable supplied, connect the transmit
module to the expansion port of the EAS
device.
Tx
Rx
Rx
Rx
Rx
Rx
Rx
Switch 7