TroubleshootingTroubleshooting
Transmit ModuleTransmit Module
If the red LED is blinking, this means that the
power line connected to the EAS device it is
connected to has noise on it. Use another EAS
device to drive the transmit module.
ReceivReceive Module(s)e Module(s)
If the red LED is glowing steadily or flickering, this
indicates that the module is either not receiving a
signal from the transmit module or the signal is
weak. Try moving the receiver 15.5 cm (6 inches)
up or down the pole to allow it to receive a stronger
signal.
Mobile checkout stands: If the signal is weak, try
moving the cart closer to the transmit module or
away from obstacles that can block the signal.
Switch settings for transmit or receive setup
DIP Switch Settings
Mode of Operation S1-1 S1-2 S1-3 S1-4 S1-5 S1-6 S1-7 S1-8
RX
60Hz
North America
Frequency hop
OFF OFF ON ON ON ON ON X
RX
50Hz
Europe
Single low frequency
ON ON OFF OFF ON ON ON ON
Europe
Single high frequency
ON ON OFF OFF ON ON ON OFF
Europe
Single frequency, auto-search
OFF ON OFF OFF ON ON ON X
TX
60Hz
North America
Frequency hop
OFF OFF ON ON ON ON OFF X
TX
50Hz
Europe
Single low frequency
ON ON OFF OFF ON ON OFF ON
Europe
Single high frequency
ON ON OFF OFF ON ON OFF OFF