User's Manual
Table Of Contents
- AMS-1070 Controller
- _
- About this Guide
- About the Product
- Installation Requirements
- Installing the Controller
- Connecting the Antennas and Remote Alarm Module
- Connecting the Noise Canceling Antennas
- Connecting to Relays in the Controller
- Connecting Power to the Controller
- Connecting a Service Laptop to the Controller
- Connecting a Modem to the Controller
- Connecting a Controller to an RS-485 Network
- Connecting a Modem to an RS-485 Network
- Specifications
- Declarations
Preliminary
AMS-1070 CONTROLLER INSTALLATION GUIDE (8200-0127-06, REV. 0)
11 of 13
Figure 15. Electrical specifications
Input Powe
r
Voltage Range: 100-240Vac (50-60Hz)
Primary Power Fuse: 1A, 250V slo-blo
Input Power: < 30 W per controller (<15 W per aisle)
Current Draw: 0.75A peak
Transmitter/Receiver Ports
Ports: 2 (2 antennas per port)
Operating freq.: 58 kHz (+
200 Hz)
Coil resistance: 13 Ohms (at 58 kHz)
Transmit current: 1 amp +/- 0.1 amps
Tx burst duration: 1.6ms
Burst rep rate: System Type 50Hz 60Hz
Two aisle 37.5 Hz 45 Hz
One aisle 75 Hz 90 Hz
Split receiver 37.5 Hz 45 Hz
Split receiver when 150 Hz 180 Hz
tag detected
Output Power: NEC Class 2
IEC950 Limited Power Source
Noise Coil Receive
r
Ports: 1 (2 antennas)
Center freq: 58 kHz