User's Manual
Table Of Contents
- AMS-1070 Controller
- _
- About this Guide
- About the Product
- Installation Requirements
- Installing the Controller
- Connecting the Antennas and Remote Alarm Module
- Connecting the Noise Canceling Antennas
- Connecting to Relays in the Controller
- Connecting Power to the Controller
- Connecting a Service Laptop to the Controller
- Connecting a Modem to the Controller
- Connecting a Controller to an RS-485 Network
- Connecting a Modem to an RS-485 Network
- Specifications
- Declarations
Preliminary
AMS-1070 CONTROLLER INSTALLATION GUIDE (8200-0127-06, REV. 0)
2 of 13
About the Product
An AMS-1070 controller is part of an Ultra•Max
®
security label detector. The controller powers and
controls up to four transceiver antennas, two
optional remote alarm modules, and two noise
canceling antenna kits. Figure 1 shows the system
components.
Figure 1. System components
Installation Requirements
Verifying Equipment and Unpacking
❑ Verify that all equipment has arrived. Make sure
the system configuration is the right one for the
installation site.
❑ Unpack major components in a back room. At
the install site, lay out parts in the order you will
need them. Do not clutter the aisle or cause a
trip hazard.
Installer/Contractor
❑ Shall have electrical work comply with the latest
national electrical code, national fire code, and
all applicable local codes and ordinances.
❑ Shall coordinate all work with other trades to
avoid interference.
❑ Shall verify existing site conditions and
coordinate with the owner’s representative and
appropriate utilities as required.
❑ Shall obtain copies of all related plans,
specifications, shop drawings and addenda to
schedule and coordinate related work.
❑ Shall thoroughly review the project to ensure
that all work meets or exceeds the above
requirements. Any alleged discrepancies shall
be brought to the attention of Sensormatic
Electronics.
!
WARNING!
Do not install this product in hazardous
areas where highly combustible or
explosive products are stored or used.
Site Requirements
Refer to Figure 2 for description of site
requirements and placement considerations.
❑ Connect the controller to a 100-240Vac source.
No fuse exchange is required for the controller.
❑ Use the appropriate power cord based on the
country of use.
❑ Replace the controller’s slow-blow fuses only
with a fuse of the same type and rating.
Tools and Equipment Required
For all controller installations:
• Phillips and slotted screwdrivers
• Wire strippers
• Cordless drill and phillips-head screwdriver bits
Ranger
Remote Alarm
Module
Controller
Antenna