AMS-1070 CONTROLLER INSTALLATION GUIDE (8200-0127-06, REV. 0)
3 of 13
Figure 2. Component placement constraints
Ref Description Distance Reason
[a] Controller to antenna separation 9m (30ft) max Tx/Rx cable length
[b] Controller to ranger separation 12m (40ft) max Ranger cable length
[c] Controller to remote alarm unit separation 9m (30ft) max Remote alarm unit cable length
[d] Controller to power outlet separation 2.3m (7.5’) max (USA)
2.5m (8’) max (non-USA)
Length of power cord
[e] Space around all sides of controller 20cm (8in) min Ventilation. May be mounted on shelf
or wall. May be hidden (e.g. checkout
counter, backroom, basement).
[a]
[b]
[c]
[d]
[e]
Controller
Ranger
Antenna
Power cord options
P/N 0351-0547-0x
-01 USA
-02 Schuko
-03 UK
-04 Japan
-05 USA line filter
-07 Australia
Power Outlet
Voltage Range: 100-240Vac (50-60Hz)
Type: Three-wire, unswitched. Do not use
orange outlets; they are dedicated to
computer equipment).
Availability 24 hours
Grounding: < 0.5Vac between neutral and ground
Loading: Cannot share line with neon signs,
motors, computers, cash registers,
terminals or data communications
equipment.
Power outlet