AMS-1070 CONTROLLER INSTALLATION GUIDE (8200-0127-06, REV. 0)
7 of 13
Connecting Power to the
Controller
!
For installation using a line cord, the
socket-outlet must be installed near
the equipment and at a location which
is easily accessible.
Für Installationen mit einem
Stromkabel m die Steckdose an
einem Standort installiert werden,
welcher einfachen Zugang erlaubt.
WARNING—RISK OF ELECTRIC
SHOCK!
The AC power line could be carrying
120Vac or 240Vac.
The AC power source can be 100-240Vac and is
connected by an ac power cord. Attach the
appropriate power cord based on the country of
use.
USA-IEC 320, 18/3, 125V, 10A, 7.5ft. 0351-0547-01
Schuko-IEC 320, 1mm sq., 250V, 10A, 2.5m 0351-0547-02
UK-IEC 320, 1mm sq., 250V, 10A, 2.5m 0351-0547-03
Japan-IEC 320, 2mm sq., 250V, 15A, 2.5m 0351-0547-04
US-Filter, Line, 125V, 6A, Plug-in 0351-0547-05
Australia to IEC 320, 2.5m, 250V, 10A 0351-0547-07
Connecting a Service
Laptop to the Controller
To use the configurator on your service laptop to
configure the controller, connect your laptop to the
Service connector on the controller.
Figure 7. Connecting a laptop to the controller
RS232 Modem
Service Laptop
Ethernet
Sync
Service
Network
AMS-1070
Controller
RJ22
male
RJ11
male
RJ11 male to RJ22
male cable