User's Manual

Table Of Contents
F-2 apC/8X Technical Manual
Figure F.1: apC/8X Template
AB
AB
AB
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
1
1
2
2
2
3
1
1
2
2
1
1
1
2
2
2
3
3
3
4
4
4
5
5
5
1
1
2
2
3
3
4
4
5
5
1
1
1
2
2
3
3
4
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
2
3
4
5
1
1
IN8IN7IN6IN 5IN3IN 2IN1
OUT1 OUT 2 OUT 3 OUT 4 OUT 5 OUT 6 OUT 7 OUT 8
IN4
IN OUT DTR
HOST
AUX
RDR
EXP R DR
AUX
STRIKE FAIL
MAIN FAIL
EXPANSION
NONONONONONONONO NCNCNCNCNCNCNCNC COMCOMCO MCOMCOMCOMCOMCOM
STRIKE BATT MAIN BATT SLAVE B SLAVE A HOST B HOST A
AB
AB
AB
AB
AB
SLAVE
RELAY OUTPUTS
SLAVE
PORT
HOST
PORT
DIAG/
AUX
PORT
STRIKE FAIL
MAIN FAIL
STRIKE BATT
MAIN BATT
SUPERVISED INPUTS
EXPANSION CONNECTORS
EXPANSION
DATA
EXPANSION
POWER
READER
PORT
AUX POWER
+12VDC
+TXD/RXD
-TXD/RXD
GND
READER PORT
WIRING
+5VDC
+12VDC
GND
POWER
IN
1&4 +12VDC
2&5 GND
1
2
3
4
5
6
ROM LO U43
ROM HI U42
SRAM ARRAY
EXPANSION BUS FOR
I32 & R48 ONLY
JUMPERS:
W1 'A' NORMAL OPERATION;'B' EMULATION
W2 OFF NORMAL; ON BYPASS TAMPER
W3 'B' NORMAL; 'A' FOR 4M EPROM/FLASH
W4 OFF NORMAL 128K SRAM; ON FOR 512K SRAM
W5 ON NORMAL; OFF SEPARATE EARTH/LOGIC GND
W6&7 OFF SLAVE EOL; ON LAST UNIT
W8&11-15 'B' HOST RS232; 'A' HOST RS485
W9&10 OFF HOST 485 EOL; ON HOST LAST UNIT
W9
P17
IN4
IN5
IN6
IN7
IN8
IN3
IN2
IN1
*
*
*
*
*
*
*
*
*FACTORY DEFAULT
SETTINGS
RS485 ONLY
RS232 ONLY
RS232 OR
RS485
RESET
SWITCH
UNDEFINED
LEDBAR
W16 OFF* 68306A; ON 68306 PROCESSOR
W2
W16
W3W4
W7
W6
SW7
SW1
SW2
SW3
SW4
SW5
SW8
P18
W10
W8
W15
P34
W5
P25
P43 P29
P22
W11
W12
W13
W14
Red ON=Reset/Fault, OFF=normal operation
Red ON=Reader error/offline reader OFF =normal
Red Reserved, OFF=normal
Yellow Reserved, OFF=normal
Yellow OFF=normal, ½ sec. flash on card read
Yellow OFF=normal, ½ sec. flash on MPT change
Yellow Toggles on host data received , ON=Off-line
Green Flashing=MPT scan, ½ sec. heartbeat
Green Flashing=Program heartbeat , 1 sec. toggle
Green ON=Power On
SW1-1 *OFF=Do not clear database
ON=Clear database on reset /powerup
SW1-2 *OFF=Online reader has amber LED on
ON=Online reader has all LEDs off
SW1-3 *OFF=3 wire RS-232 or 4 wire RS-485
ON=5 wire RS-232 enabled
SW1-4 *OFF=Direct connect enabled
ON=Dialup enabled
SW1-7
SW1-6 SW1-5 BAUD RATE
*OFF *OFF *OFF 9600
OFF OFF ON 19200
OFF ON OFF 1200
OFF ON ON 2400
ON OFF OFF 4800
ON OFF ON 2400, X.25
ON ON OFF 4800, X.25
ON ON ON 9600, X.25
SW1-8 *OFF=8-bit, even parity, ON=8-bit, no parity
SW3-1 *OFF=card entry at keypad disabled
ON=card entry at keypad enabled
SW3-2 *OFF=normal reader LED access pattern
ON=single LED access pattern enabled
SW3-3 *OFF=card numbers up to 32 bits long
ON=card numbers up to 16 bits
SW3-4 *OFF=doesn’t store/test act/deactivate dates
ON=store/test activate/deactivate dates
SW3-5 *OFF=don’t store local APB in card record
ON=store local APB in card record
SW3-6 *OFF=don’t store local elevator data in card
ON=store local elevator data in card
SW3-7 *OFF=Magstripe encryption disabled
ON=Magstripe encryption enabled
SW3-8 *OFF=reverse card swipe is not duress
ON=reverse card swipe is duress
W1
SW2-1 *OFF=DFO relay link disabled
ON=DFO relay link enabled
SW2-2 *OFF=DHO relay link disabled
ON=DHO relay link enabled
SW2-3 *OFF=panel offline relay link disabled
ON=offline relay link enabled
SW2-5
SW2-4 Floor Selection Input (FSI)
*OFF *OFF No inputs used for elevator FSI
OFF ON Only input 1 used for FSI
ON X All inputs used for elevator FSI
SW2-6 *OFF=reader keypad used for floor selection
ON=reader keypad used for PIN
SW2-7 *OFF=card misreads reported
ON=card misreads ignored
SW2-8 *OFF=AUX port used for apC Test Program
ON=AUX port used for local printout
Address Switch
Translation
HI
LO UNIT
0 0 1
0 1 2
0 2 3
0 3 4
0 4 5
0 5 6
0 6 7
0 7 8
0 8 9
0 9 10
0 A 11
0 B 12
0 C 13
0 D 14
0 E 15
0 F 16
1 0 17
1 1 18
etc.