User's Manual

Table Of Contents
F-12 apC/8X Technical Manual
Figure F.11: Wiegand/Proximity Wiring to the RM-4
9
HOLD
BEEP
RED
L
GRN
L
RTN
D1
D0
GND
+12V
1
1
1
RM J3
RM J4
MINIPROX
DC+
GND
D
0
D1
RTN
GREEN
LED
RED
LED
BEEPER
HOLD
TAMPER
C
TAMPER
S
1
1
RM J3
RM J4
PROXPRO
1
11
DC+
GND
D
0
D1
RTN
GREEN
LED
RED
LED
BEEPER
HOLD
TAMPER
C
TAMPER
S
1
1
RM J3
RM J4
MAXIPROX
1
11
24 VDC
POWER
SUPPLY
NOTES:
THE MINIPROX AND PROXPRO CAN EACH
DRAW
175MA MAX. DEPENDING ON
YOUR SYSTEM CONFIG., THIS MAY
EXCEED THE APC'S POWER SUPPLY
RATING AND EXTERNAL POWER MAY BE
REQUIRED FOR THE READERS.
THE MAXIPROX NEEDS AN EXTERNAL
24
VDC LINEAR POWER SUPPLY WITH A
COMMON GROUND TO THE RM-4 AND
MAXIPROX.