apC/8X Physical Requirements
apC/8X Technical Manual 2-5
* For plenum or underground applications:
Use Manhattan M63995 for 2 pair only, 150 ohm, 8.8 pf/ft to Belden
89182 for 1 pair 22 AWG, 100 ohm 12.95 pf/ft. Control, Supervised
Input cables must be shielded for FCC Class B operation.
You can also substitute the following plenum-rated cables:
Manhattan (PN#M63995) for 2-pair only, 24 AWG, 120 ohm, 12.5 pf/ft,
with foil shield. For the apC/8X-to-RM connection, use only one of the
pairs.
Belden 89729 for 2-pair, 24 AWG, 150 ohm, 8.8 pf/ft. Use Belden 89182
for 1-pair 22 AWG, 100 ohm, 12.95 pf/ft., with foil shield. These two
cables are also rated for underground burial.
Reader Wiegand Prox
Star Coupler
Indala 9536/9537 24 3 Yes 500 ft.
Sensor 9941 22 5-wire Yes 500 ft.
Hughes/IDI 8723 22 2 Yes 500 ft.
Table 2.2: Equipment Wiring Specifications
Signal From To Belden# Gauge # Prs Shielded?
Max
Length