TP-MS608/616 Power Source Equipment (Power over Ethernet Hub) USER’S MANUAL TYCON POWER SYSTEMS
User’s Manual TP-MS608/616 Contents 1. Introduction........................................................................... Features................................................................................................ Package Contents................................................................................. 2. Hardware Description........................................................... Physical Dimension..............................................................................
User’s Manual TP-MS608/616 1. Introduction TYCON’s family of Power over Ethernet PSE (Power Sourcing Equipment), injects power over data-carrying Ethernet cabling. The TP-MS608/616, support 8 and 16 ports respectively in a 10/100/1000BaseTx Ethernet network, over TIA/EIA-568 Category 5/5e/6 cabling. DC operating power, for data terminal units, is fed over data pairs of the cabling (4/5 and 7/8).
User’s Manual TP-MS608/616 Package Contents Unpack the contents of the TP-MS608/616 and verify them against the checklist below. TP-MS608/616 x 1 Power Cord x 1 Bracket x 2 ( for 19” rack mounted) CD-ROM x 1 (Software Utility + User Manual) Compare the contents of your TP-MS608/616 package with the standard checklist above. IF any item is missing or damaged, please contact your local dealer for service. 2.
User’s Manual TP-MS608/616 The Front Panel of the TP-MS608/616 consists of 8/16 x RJ-45 Ethernet ports (data), 8/16 x RJ-45 PoE ports (data + power), 8/16 x LED port indicators, one LED power indicator and one RJ-45 remote control port(include one LED). LED Indicators The LED Indicators gives real-time information of systematic operation status. The following table provides descriptions of LED status and their meaning.
User’s Manual TP-MS608/616 Rear Panel The AC inlet, DC input terminal, and 2 Ventilation fan are located at the rear panel of the TP-MS608/616. The device will work with AC in the range 100-240V AC, 50-60Hz. Or work with DC -48V. (-42~-57VDC) Power On Connect the power cord to the power socket on the rear panel of the PSE. The other side of power cord connects to the power outlet.
User’s Manual TP-MS608/616 RJ-45 Remote Control Port TP-MS608/616 can remotely manage the PoE via the network. To manage TP-MS608/616, you must to set the TP-MS608/616 TCP/IP parameter. TP-MS608/616 allowed you to use a standard Web-browser such as Microsoft Internet Explorer or Mozila, to set the TCP/IP parameter. Before you use the web interface to set the PoE TCP/IP, verify that TP-MS608/616 is properly installed on your network and PC on the network can access PoE via the web-browser. 1.
User’s Manual TP-MS608/616 9. Key in ID (user name) and password to enter PoE TCP/IP parameter setting. Default ID and password is admin and system. 10. TP-MS608/616 TCP/IP parameter has 4 pages interface (administrator setting, TCP Mode, UDP Mode and UART). You must change the administrator & TCP mode to fit your network.
User’s Manual TP-MS608/616 11. Administrator setting: you can assign nickname, IP setting, user name, password and view system information. Nickname: You can assign a name to the device. IP Address: You must assign the IP address reserved by your network. The default IP is 192.168.1.10. Subnet Mask: You can assign the subnet mask for the IP address. The default subnet mask is 255.255.255.0. Gateway: You can assign the gateway here. The default gateway is 192.168.1.1.
User’s Manual TP-MS608/616 12. TCP Mode: You can update the TCP control parameter here. Telnet Server/Client: Set to Server for PoE management operation. Port Number: You can assign port number for TCP/IP operation. The default Port Number is 23. Remote Server IP Address: Unused. Clint mode inactive timeout: Unused. Server mode protect timeout: Set to 0(Disable) for normal operation. When you have finished the set up, click on Update to update your setting.
User’s Manual TP-MS608/616 13. UDP Mode: This mode is not used in the PoE application.
User’s Manual TP-MS608/616 14. UART: You must set UART Control to RS232,9600,8,N,1 for PoE operation. Mode: Set to RS232 for PoE operation. Baud rate: Set to 9600 bps for PoE operation. Character Bits: Set to 8 bits for PoE operation. Parity Type: Set to none parity for PoE operation. Stop Bit: Set to 1 stop bit for PoE operation. Hardware Flow Control: Set to none flow control for PoE operation. When you have finished the set up, click on Update to update your setting.
User’s Manual TP-MS608/616 15. When you have configured your set up, you must reset the device to take effect.
User’s Manual TP-MS608/616 3. Software Utility Installation Before you start to remote configuring PD, please install the software utility. Through the software utility, you can easily to control the PD that connect with PoE and view the PD parameter information. The software utility provides GUI interface and user can easily to start with it. The software utility supports Windows environment – Window 98, 2000, XP,Vista and Window 7. Please follow the below steps to install the software utility. 1.
User’s Manual TP-MS608/616 4. GUI Management Display and Illustration Connect the PSE with a PC through the remote control port. Then, run the software utility (Netclient). You will see the main utility interface below.
User’s Manual TP-MS608/616 System Login Run the management software or click “File”, and select “Login”, the system will show the diagram below.
User’s Manual TP-MS608/616 Modify Password Click “File” and select “Modify PSW”, you can modify the password, the system permits 3 sets of password.
User’s Manual TP-MS608/616 Edit Station TCP/IP In the TCP/IP Status display window, you can edit the station name, TCP/IP address and port number. Click the Edit icon to modify this parameter. In the Edit window, click the View icon to display TCP/IP parameter. Station Name: You can assign a name to the PSE device. Address: You can assign the IP address for this PSE station. Port:: You can assign the port number for this PSE station.
User’s Manual TP-MS608/616 Edit Remote PoE IP In the TCP/IP Status display window, you can use “PoE IP Setting” icon to start the web-browser. To modify the remote PoE TCP/IP parameter, please reference RJ-45 Remote Control Port of section 2 Hardware Description (page 7). Change Browse icon: You can use this icon to change the web-browser for remote PoE IP edit. The default web-browser is Microsoft Internet Explorer.
User’s Manual TP-MS608/616 GUI Connect In the TCP/IP Status display window, edit TCP/IP parameter, then click “GUI” and select “Connect All” command or click “connect” icon, if the Station Select window shows the name icon and displays power status(green or red) light, it means that the PSE connection is correct. You can then select station to configure you PSE.
User’s Manual TP-MS608/616 GUI connect example: In the Station Selection window, the LED indicates real time connection of PSE. Green-----this connection and PSE power are normal. Red--------this connection is OK but PSE power is not correct. Orange---this connection is not working.. Gray-------this station is not setting. In the TCP/IP Status window, the LED indicates real time status of TCP/IP. Green-----TCP/IP connection is OK. Red--------TCP/IP connection is not working.
User’s Manual TP-MS608/616 Station and Status Window Select The PSE management software can monitor 8 PSE simultaneously. In the GUI Disconnect mode, only the TCP/IP Status display window can be used to set the TCP/IP parameter. In the GUI Connector mode, there three display windows can choose - TCP/IP Status/Port Status/Board Status. Port status and Board Status show relative PSE Station status. If you want to change the status display window, only use the mouse to choose the relative word icon.
User’s Manual TP-MS608/616 Configuration In the “Module” window, select the suitable port that you require, then, click “Config”, and select “Setup”, the screen will show the system control panel as below. Set icon: Apply the operation mode to PSE system. Set Enable/Set Disable icon: Change the Board Status window to set enable/disable. Factory icon: Apply the factory setting to PSE system. You can setup Operation Mode/ AC Disconnect/ DC Disconnect of each port individually, then, click “Set”.
User’s Manual TP-MS608/616 Factory Setting Click “Config”, and select “Factory” or click the “Factory” icon. The screen will show the factory setting control panel as below: then click “Y” for the Factory Setting.
User’s Manual TP-MS608/616 Factory setting as below: Operation Mode → Auto (Auto, Force & Shutdown) AC Disconnect → On (On & Off) DC Disconnect → Off (On & Off) 25 TYCON POWER SYSTEMS
User’s Manual TP-MS608/616 Board Status Click “Config”, and select “GetBoardStatus”, or click “Board STATUS” icon, the screen will show current status of each port.
User’s Manual TP-MS608/616 Port Status In the “Module” window, select the suitable port that you require, then, click “StatusDisp”, and select “PortStatus”, or click the “PORT STATUS” icon, the screen will show current status of each port and current power supply status of each module. If all power modules are working normally, the “Sys. Power” will show a green light, if any module has failed, the light will turn to red.
User’s Manual TP-MS608/616 GUI Version Click “StatusDisp”, and select “GUI Version”, the screen will show the version of the EMS utility 28 TYCON POWER SYSTEMS
User’s Manual TP-MS608/616 GUI Disconnect Click the “GUI”, and select “Disconnect All”, or click the “GUI disconnect” icon to disconnect the communication between GUI and PSE.
User’s Manual TP-MS608/616 File Open and Save You may click “File” and select “Open”, or click the ”Open file” icon, to open the previous setting file. Click “Save”, or “Save file” icon, to save the current setting.
User’s Manual TP-MS608/616 5.