Manual

User’s Manual TP-MS608/616
23
T
Y
C
O
N
P
O
WE
R
S
Y
S
T
E
M
S
Configuration
In the “Module” window, select the suitable port that you require, then, click Config”,
and select “Setup”, the screen will show the system control panel as below.
Set icon: Apply the operation mode to PSE system.
Set Enable/Set Disable icon: Change the Board Status window to set enable/disable.
Factory icon: Apply the factory setting to PSE system.
You can setup Operation Mode/ AC Disconnect/ DC Disconnect of each port
individually, then, click “Set”.
PSE port operates in one of three modes: auto mode, force mode and shutdown
mode. In auto mode, the port will detect and classify a PD to connect to, then
immediately turn on the power if the detection was successful. In force mode, the
port will not detect and classify a PD to connect to, but immediately turn on the
power to the port. In shutdown mode, the port is disabled and does not detect or
power on a PD.